Picture 22. Temporary connection of controller
Jumper
3.6
Temporary connection of lift
When the lift is installed, it is sometimes necessary to operate the lift functions in order to change the posi-
tions of the cylinders and the 1st booms. Temporarily connect the lift to enable the lift functions.
1. Connect the controller to the relay card.
2. Connect earth connection (GND) and +12/24V to the quick connectors on the main power cables of the lift.
3.
When operating, connect a cable between an available power supply connection (+) and CS on the relay
card to simulate switch CS in the On position. Remove the jumper immediately after completed operation.
m
WARNING!
Take great care when running the lift functions and make sure nothing gets trapped: risk of injury and
material damage.
3.6.1 Battery maintenance
When the lift is operated repeatedly during installation, use the battery charger between operations to main-
tain battery charge.
The battery charger must not be connected when operating the lift. Risk of material damage.