ZT MK2
Safety rules
11
www.zepro.com
3.2
Calculating installation dimensions (standard lift)
For easier installation it is useful to calculate and specify the necessary dimensions in advance. Efforts
should be made to install the lift as high as possible. (ZS)
The platform and 1st boom combinations are optimized for minimum total length (O). Aim to install the slide
profile in a position that allows the rear edge of the platform in the folded position to align with the rear edge
of the vehicle body. In this way, it is guaranteed that the platform can be folded out.
The easiest way to calculated the installation dimensions is to use a CAD program. 2D drawings are available
for downloading from www.c-office.com. For help with calculating installation dimensions, contact ZEPRO.
Phone: +46 (0)10-459 05 04, Email: [email protected].
Arm
Lifting
height
Slide profile
(length)
B
Lift platform
(length)
O
1565
1669
135
1356
1590
989*
1765
1769
1965
1869
1565
1789
155
1542
1700
1109*
1765
1889
1965
1989
* Applies to 50 mm bavetta. With a 70 mm bavetta, dimension (B) is reduced by 20 mm.
Length of slide profile
100
115
B
Total overhang (O)
495
Picture 9. Installation dimensions
46
36
All dimensions specified in millimetres