ZN 2500-130/150
36
Installation
www.zepro.com
4.11.3
Tail lift with angle sensor IFM for autotilt
1. Install the angle sensor on the platform using the nuts, bolts and washers supplied and attach the cable
using cable time; see Image 59
2. Route the cables and secure with cable ties.
Connection is described later in section
6.
Image 59. Installing an angle sensor for auto tilt
Bracket on the platform
Autotilt angle setting
By default, the autotilt angle is set to 0°. If necessary, the position
of the angle sensor (autotilt angle) can be adjusted.
1. Loosen the two screws without removing them, see Image 60.
2. Adjust the position of the angle sensor to the desired angle,
see Image 60.
3. Retighten the screws.
Image 60. Adjusting the autotilt angle
Summary of Contents for ZN 2500-130