ZN 2500-130/150
44
Connection
www.zepro.com
6
Connection
6.1
Cable grommet
6.1.1
Before connection
1. Disconnect the cable grommet’s protective cover, which is secured with three screws; see Image 75.
2.
Loosen the five screws on the cable grommet, see
Image 76. Cables can now be installed/removed/adjusted
in the grommet. The cable should be installed together with existing cabling using cable ties. Ensure the
length of the cable is sufficient. The outer casing should be stripped back 350 mm. See
Image 77.
6.1.2
After connection
1.
Tighten the five screws once all cables are suitably located in the cable grommet, see
Image 76.
Tightening torque: 5 Nm.
2. Install the cable grommet’s protective cover with the three bolts provided, see Image 75.
Tightening torque: 8 Nm.
Image 75.
Fasten the cable grommet’s pro
-
tective cover with three screws
350 mm.
Image 76.
Cable grommet's five screws
Image 77.
The outer casing of cables should be stripped 350 mm.
Summary of Contents for ZN 2500-130