Z 2500-130/150
28
Installation
www.zepro.com
Image 41. Fit end stops between the lift arms
and the rear beam of the vehicle floor
Image 42. The angle sensor allows autotilt function
when the angle of the lift arm is horizontal or lower.
Image 43. Installing the angle sensor
Left
Right
6.9
Armstops
Fit end stops between the lift arms and the rear
member of the vehicle floor. The left and right end
stops must be reached at the same time, as high up
the lift arm as possible. Installation must take place
against the vehicle body.
It is not permitted to perform welding in the lift
arm. Installation must take place against the
vehicle body.
m
WARNING!
6.10
Angle sensor
If the lift is fitted with electronic autotilt, install the
angle sensor on the 1st boom, see Image 42. The
angle sensor allows autotilt function when the angle
of the lift arm is horizontal or lower.
When installing on the left arm, the sensor’s cable
input must be facing upwards. When installing on
the right arm, the sensor’s cable input must be
facing downwards.
NOTE.
Summary of Contents for Z 2500-130 Series
Page 2: ......
Page 77: ...Z 2500 130 150 Specifications 77 www zepro com Image 92 Loading diagram 18 4 Loading diagram ...
Page 79: ......