Z 2500-130/150
50
Functional description Z 2500 MA Autotilt (standard)
www.zepro.com
See also the electrical diagram
: "9.1 Z2500-130/150 MA with electrical autotilt" on
page 41.
Function
Input signal
Inclinometer
Output signal
Comment
Controller
Illustration
High Low (0v)
Lift
1
B
p
Di1
p
Di2***
p
Di3
p
Di4
p
Di5
p
Di6
0°
p
U0
p
U1
p
U2
p
U3
p
U4
p
U5
p
U6
p
U7
Autotilt up
p
Ctrl 1
p
Ctrl 2
p
Ctrl 3
p
Ctrl 4
p
Ctrl 5
p
Ctrl 6
-10º
0º
2
B
p
Di1
p
Di2***
p
Di3
p
Di4
p
Di5
p
Di6
0°
p
U0
p
U1
p
U2
p
U3
p
U4
p
U5
p
U6
p
U7
p
Ctrl 1
p
Ctrl 2
p
Ctrl 3
p
Ctrl 4
p
Ctrl 5
p
Ctrl 6
Tilt up
B
C
p
Di1
p
Di2
p
Di3***
p
Di4
p
Di5
p
Di6
0°
p
U0
p
U1
p
U2
p
U3
p
U4
p
U5
p
U6
p
U7
p
Ctrl 1
p
Ctrl 2
p
Ctrl 3
p
Ctrl 4
p
Ctrl 5
p
Ctrl 6
45º
-10º
Close
B
C
2H
0°
p
U0
p
U1
p
U2
p
U3
p
U4
p
U5
p
U6
p
U7
p
Ctrl 1
p
Ctrl 2
p
Ctrl 3
p
Ctrl 4
p
Ctrl 5
p
Ctrl 6
* Only required at start of travel; it is ignored after breakover of sensor until repositioned.
** 0.5 second delay of output signal.
*** Not connected
Ai1
Ai1
Ai1
Ai1
Does not affect
function
Does not affect
function
Summary of Contents for Z 2500-130 Series