Z 2500-130/150
Functional description Z 2500 MA
53
www.zepro.com
11
Functional description Z 2500 MA
11.1
Sensor
Name
Position
(standard)
Function
Description
Ai 1
Not used in this configuration
Ai 2
Not used in this configuration
B
Controller
Up button
E
Controller
Down button
C
Controller
Tilt button
Used in combination with B and E for tilt up and tilt down
2H
Controller
Two-hand but-
ton
Activated in connection with opening and closing of vehicle
body. Used for quick opening.
Di1
Not used in this configuration
Di2
Not used in this configuration
Di3
Angle sensor
Non-actuated Di3 disables Tilt up with the secondary control
device so that the operator must use the two-hand button
- 2H together with the primary control device in order to
continue to maintain the tilt up function.
Di4
Tilting cylinder
Open platform
alarm
Pressure switch for falling pressure connected to +side of
tilting cylinder. In its actuated state, returns the connection
signal (+) to Di4, resulting in output signal (-) at Pa-. At the
same time (+) signal is sent on Pa+. 60 Bar (NC).
Di5
Not used in this configuration
Di6
Not used in this configuration
Cs
Cab
Activation
No signal in at Cs results in blocked control device terminals.
Signal to Cs usually comes from the cab switch. In individual
cases, where the cab switch is not used, the (+) signal
coming in to Cs is jumpered from (CS PWR) on nearby
terminal.
2H
Controller
Two-hand but-
ton
Activated in connection with opening and closing of vehicle
body. Used for quick opening.
See also the electrical diagram
: "9.2 Z2500-130/150 MA" on page 42.
Summary of Contents for Z 2500-130 Series
Page 2: ......
Page 77: ...Z 2500 130 150 Specifications 77 www zepro com Image 92 Loading diagram 18 4 Loading diagram ...
Page 79: ......