Zennio GetFace IP
http://www.zennio.com
Tecnical Support
:
http://support.zennio.com
23
Basic Settings
:
Button Function During Call
: configures the function of the quick dial button
during a call. This only applies to the button the call was started with. It is
recommended to leave this button non-functional during calls, otherwise the
calls may be finished by mistake.
Restore Network Settings By Buttons
: this option allows restoring the
network default settings through a quick dial buttons sequence (see section 3
for more information).
The default button settings can be restored through the
Reset
button. This allows
erasing the configuration of the buttons and their modules. Likewise, button
assignments can be erased through the
Clear
button.
Up to 146 quick dial buttons can be configured in
Quick Dial Buttons
. These buttons
are grouped into five-button modules (up to 29 modules) along with the button
incorporated in the video intercom. Each button must correspond with the user
associated to a particular dwelling (see section 3.1.3.1 for more information).
3.1.6
DOOR SWITCH CONFIGURATION (HARDWARE/DIGITAL INPUTS)
The
REX Input Control
section allows configuring one of the Zennio GetFace IP inputs
to work as an output button, so that one output gets opened after that input gets
activated. If an indoor switch to operate the door opening is required, this feature will
be useful.
Figure 16
Door Switch
– REX Input Control