background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zennio KNX-IP Router PLess 

 Zennio KNX-IP Interface PLess 

 

 

Router and Interface KNX to IP 

 

 

 

 

 

 

 

 

 

ZSY-IPR-PL  

 ZSY-IPI-PL   

U

S

E

R

 M

A

N

U

A

L

 

  

 

Application Program version Zennio KNX-IP Router PLess: [1.1]  

Application Program version Zennio KNX-IP Interface PLess: [1.0] 

User Manual version: [1.1]_b 

 

 

www.zennio.com

  

 

 

Summary of Contents for ZSY-IPR-PL

Page 1: ...nterface PLess Router and Interface KNX to IP ZSY IPR PL ZSY IPI PL USER MANUAL Application Program version Zennio KNX IP Router PLess 1 1 Application Program version Zennio KNX IP Interface PLess 1 0...

Page 2: ...Parallel Downloads 7 1 3 2 Limitations 8 2 Description 9 2 1 KNX to IP Interface 9 2 2 Line or area coupler 9 2 3 Telegram Filtering 11 2 4 LED Indicators 13 2 5 Manual Function Button 16 2 5 1 Manua...

Page 3: ...ATES Version Changes Page s 1 1 _b Changes in the web interface The IP address of the tunnelling addresses in use is displayed Changes in the document Minor corrections 20 1 1 _a Changes in the Zennio...

Page 4: ...solution Zennio KNX IP Router PLess can be used as line or area coupler to provide data connection between the upper KNXnet IP line and the lower KNX twisted pair bus line Figure 1 Context Topology Bo...

Page 5: ...missions etc one more indicator per line for the state of the filtering function and one additional indicator for the programming mode Only in Zennio KNX IP Router PLess Use as an area or line coupler...

Page 6: ...ess in programming mode After a short press the programming LED 9 will light in red The behaviour of the additional LEDs and the manual function button will be described in sections 2 4 and 2 5 For de...

Page 7: ...Less as a programmer in ETS it needs to be connected to the same IP network as the PC 1 3 1 PARALLEL DOWNLOADS ETS offers the option to perform multiple parallel downloads within the same project This...

Page 8: ...o parallel downloads they are not available to download physical addresses When performing this type of downloads the link device used by ETS is not the one configured for the line but the general one...

Page 9: ...ual address should be assigned in order to download the parameters 2 2 LINE OR AREA COUPLER Note this functionality does not apply to Zennio KNX IP Interface PLess Zennio KNX IP Router PLess can be us...

Page 10: ...ed a physical address prior to downloading the new parameterisation Whatever the location in the topology Zennio KNX IP Router PLess offers an insulated coupling interface with the possibility in the...

Page 11: ...ther side if the address is found or drop block it if it is not Note making further changes to a project addresses etc requires downloading the updated filter table to the line coupler Example if the...

Page 12: ...wn in Figure 5 if the coupler with address 3 2 0 reads a telegram on the mainline destined to a device with individual address 3 1 2 it will compare both addresses and conclude that 3 1 2 does not bel...

Page 13: ...OFF error or mainline not connected or not powered ON green Ethernet connection OK ON orange manual function in execution or factory reset preparation Note the LED colours are independent It must be t...

Page 14: ...e traffic status in the secondary bus BLINKING green traffic OFF no traffic BLINKING red errors in the transmissions Group Address GA Filter Status LED shows the current configuration of the group add...

Page 15: ...ses blocked Notes These LEDs are non functional in Zennio KNX IP Interface PLess Please be careful not to confuse yellow and orange Programming LED OFF normal operation ON red programming mode active...

Page 16: ...manual function and will turn the main bus status LED orange or red depending on the previous status of the LED green or off Depending on the parameterised manual function other LEDs may also change t...

Page 17: ...s and physical telegrams Zennio KNX IP Interface PLess Physical address 15 15 255 Host name KNX IP Interface see section 3 1 DHCP activated These are the steps to restore the factory settings Press th...

Page 18: ...its of the MAC address of the device will be equivalent Zennio KNX IP Router PLess http KNX IPrt xxxxxx 8080 Zennio KNX IP Interface PLess http KNX IPif xxxxxx 8080 The IP address of the device can be...

Page 19: ...es shows the additional individual addresses for the tunneling function see section 2 6 2 1 Set Tunneling Addresses allows defining additional individual addresses for the tunneling function see secti...

Page 20: ...device itself Up to four simultaneous connections are possible which implies that up to four different individual addresses must be configured When a tunneling address are being used the IP address t...

Page 21: ...Router Interface PLess http www zennio com Technical Support http support zennio com 21 Figure 12 Configuration of the first tunneling address in ETS4 Figure 13 Configuration of the first tunneling ad...

Page 22: ...he manual function button Wait for the Status update authorized message on the screen Request the update From the Update section press the Request Update button and wait until the device reboots and e...

Page 23: ...p support zennio com 23 During the Boot mode the TP line status LED indicator blinks in green Notes The Boot mode can be alternatively accessed by disconnecting the power supply and re connecting it w...

Page 24: ...the Zennio KNX IP Router PLess Application Program Next the device should be added to the project where desired When intending to use the device as a programming interface it will be necessary to acc...

Page 25: ...Area Coupler Figure 17 Zennio KNX IP Router PLess as a Line Coupler Finally the configuration process begins by entering the Parameters tab of the device The following sections provide a detailed expl...

Page 26: ...n only in Zennio KNX IP Router PLess sets the desired function to be executed by the device while in the manual mode The available values are Disabled no action Transmit All Telegrams the device will...

Page 27: ...P Configuration tab Zennio KNX IP Router Interface PLess is provided with the DHCP protocol Do Not Use Use enabled by default and therefore can gain an IP address automatically as long as a DHCP serve...

Page 28: ...y to Zennio KNX IP Interface PLess Telegrams sent from the KNX bus to the IP network or vice versa travel through the latter as multicast IP packets addressed to port 3671 at IP address number 224 0 2...

Page 29: ...n of each parameter option Custom The available options are Groups Addr Filter Physical Addr Block enables the group address filtering and drops all telegrams destined to physical addresses Groups Add...

Page 30: ...evice regarding telegrams destined to individual addresses Note transmitting all telegrams no telegram filtering or dropping is intended for diagnostic purposes and may cause risks or conflicts or gen...

Page 31: ...undelivered telegram will be re sent up to three times Reduced the undelivered telegram will be re sent once Group Addresses Repetition if Errors on Line No Normal Reducida sets the desired reaction u...

Page 32: ...the telegram will show as confirmed on it therefore preventing repetitions in case of faulty projects etc even if no device is receiving it In case of reception errors on the destination line negativ...

Page 33: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...