Z35
http://www.zennio.com
Tecnical Support:
http://support.zennio.com
15
“After Programming and Reset”: combination of the two above options.
Screensaver
[
disabled
/enabled
]:
enables or disables the “Screensaver” tab in
the tree on the left. See section 3.1.6 for details.
Time to Consider Inactivity
[
1
…65535
] [
s/
min
/h
]: time that must elapse since
the last press and/or proximity detection to consider inactivity state. Then the
display backlight will dim. See section 3.1.3.
Proximity Sensor
[
disabled
/enabled
]: enables the proximity sensor. This
functionality permits “waking up” the device display when detecting presence
through the proximity sensor
Please refer to the user manual
“Proximity and Luminosity Sensor”
(available
in the Z35 product section at the Zennio homepage,
www.zennio.com
) for
detailed information about the functionality and the configuration of the related
parameters.
Ambient Luminosity Sensor
[
disabled
/enabled
]: enables or disables the
ambient luminosity sensor. When enabled, a new tab is added in the tree on the
left (see section 3.1.7).
Touch Locking
[
disabled
/enabled
]: enables or disables the possibility of locking
the touch by object. When enabled, a new tab is added in the tree on the left (see
section 3.1.8).
Sounds
[
Default
/Custom
]: sets whether the sound functions (button beeps,
alarm and doorbell) should work according to the pre-defined configuration
(“Default”) or to a user-defined configuration (“Custom”) (see section 3.1.9).
Advanced Configuration
[
enabled
/disabled
]: enables or disables the
“Advanced” tab in the tree on the left (see section 3.1.10).
The project topology shows the following objects by default:
[General] Time
: 3-byte object for setting the internal time of the device, for
example, by linking it to a KNX clock. This object also allows read requests, so
the current time of the device can be checked. It is also automatically sent after
time changes made by the user from the screen itself.
Note
:
although the DPT of this object considers a field for setting the day of the
week, Z35 calculates it from the date and therefore ignores that field.