inBOX 24 vT / inBOX 20 vT
Technical Support:
30
121, 150, 179, 208
1 Bit
I
C - W - -
DPT_Start
0/1
[Ix] External Motion Detection
0 = Nothing; 1 = Motion detected
by an external sensor
122, 127, 132, 151, 156, 161,
180, 185, 190, 209, 214, 219
1 Byte
O
C R - T -
DPT_Scaling
0% - 100%
[Ix] [Cx] Detection State (Scaling)
0-100%
123, 128, 133, 152, 157, 162,
181, 186, 191, 210, 215, 220
1 Byte
O
C R - T -
DPT_HVACMode
1=Comfort
2=Standby
3=Economy
4=Building
Protection
[Ix] [Cx] Detection State (HVAC)
Auto, Comfort, Standby, Economy,
Building Protection
124, 129, 134, 153, 158, 163,
182, 187, 192, 211, 216, 221
1 Bit
O
C R - T -
DPT_Switch
0/1
[Ix] [Cx] Detection State (Binary)
Binary Value
125, 130, 135, 154, 159, 164,
183, 188, 193, 212, 217, 222
1 Bit
I
C - W - -
DPT_Enable
0/1
[Ix] [Cx] Enable Channel
According to parameters
126, 131, 136, 155, 160, 165,
184, 189, 194, 213, 218, 223
1 Bit
I
C - W - -
DPT_Switch
0/1
[Ix] [Cx] Force State
0 = No Detection; 1 = Detection
224, 235
1 Byte
I
C - W - -
DPT_SceneControl
0-63; 128-191
[Ox] Scenes
0
–
63 (Execute 1
–
64); 128
–
191 (Save 1
–
64)
225, 236
1 Bit
I
C - W - -
DPT_BinaryValue
0/1
[Ox] On/Off
N.O. (0=Open Relay; 1=Close
Relay)
1 Bit
I
C - W - -
DPT_BinaryValue
0/1
[Ox] On/Off
N.C. (0=Close Relay; 1= Open
Relay)
226, 237
1 Bit
O
C R - T -
DPT_BinaryValue
0/1
[Ox] On/Off (Status)
0=Output Off; 1=Output On
227, 238
1 Bit
I
C - W - -
DPT_Enable
0/1
[Ox] Lock
0=Unlock; 1=Lock
228, 239
1 Bit
I
C - W - -
DPT_Start
0/1
[Ox] Timer
0=Switch Off; 1=Switch On
229, 240
1 Bit
I
C - W - -
DPT_Start
0/1
[Ox] Flashing
0=Stop; 1=Start
230, 241
1 Bit
I
C - W - -
DPT_Alarm
0/1
[Ox] Alarm
0=Normal; 1=Alarm
1 Bit
I
C - W - -
DPT_Alarm
0/1
[Ox] Alarm
0=Alarm; 1=Normal
231, 242
1 Bit
I
C - W - -
DPT_Ack
0/1
[Ox] Unfreeze Alarm
Alarm=0 + Unfreeze=1 => End
Alarm
232, 243
1 Bit
O
C R - T -
DPT_State
0/1
[Ox] Warning Time (Status)
0=Normal; 1=Warning
233, 244
4 Bytes
I/O
C R W T -
DPT_LongDeltaTimeSec
-2147483648 -
2147483647
[Ox] Operating Time (s)
Time in Seconds
234, 245
2 Bytes
I/O
C R W T -
DPT_TimePeriodHrs
0 - 65535
[Ox] Operating Time (h)
Time in Hours
246
1 Byte
I
C - W - -
DPT_SceneControl
0-63; 128-191
[Shutter] Scenes
0 - 63 (Execute 1 - 64); 128 - 191
(Save 1 - 64)
247
1 Bit
I
C - W - -
DPT_UpDown
0/1
[CA] Move
0 = Raise; 1 = Lower
248
1 Bit
I
C - W - -
DPT_Step
0/1
[CA] Stop/Step
0 = Stop/StepUp; 1 =
Stop/StepDown
1 Bit
I
C - W - -
DPT_Trigger
0/1
[CA] Stop
0 = Stop; 1 = Stop
249
1 Bit
I
C - W - -
DPT_Trigger
0/1
[CA] Switched Control
0, 1 = Up, Down or Stop,