Tudor water heaters are fully automatic, and may be left switched ON under
the control of the variable thermostat.
Nominal operating temperature can be varied from about 30°C to about 80°C.
Temperature should not be set to less than 60°C without due regard to
regulations governing the storage temperature of hot water.
Economy Setting
The economy setting “E” will maintain stored water temperature at
approximately 60°C. At the “E” setting, the temperature control locates into a
set position and a slight resistance will be felt when rotating the temperature
control beyond that setting. This measure is to help ensure that higher
temperatures are only selected deliberately.
Frost Protection
If the heater is located where ambient air temperature could fall below 5°C
when the heater is not in use, the “anti freeze” setting on the temperature
control will maintain stored water temperature over 5°C to prevent freezing
and damage to the water heater.
The same protection does not extend to connecting pipework or fittings.
Safety Cutout
Should the heater over-heat, a manually resettable safety cutout will
automatically turn the heating element OFF. The cutout must be reset by a
Service Provider or a licensed electrician. Users should never reset the cutout
without qualified assistance.
Cleaning
Never use strong, corrosive or abrasive cleaning materials. Wipe clean the
outer surfaces with a sponge or soft cloth using a mild soap and water.
Domestic dish washing liquid detergent is most suitable.
ECONOMY
HIGH
OFF
ANTI-
FREEZE
LOW
PART NO DESCRIPTION
90401NZ element neck ring kit Tudor
90407NZ fascia kit Tudor undersink
90408NZ fascia kit Tudor oversink
90836NZ element kit
90420NZ pilot light kit Tudor
90421NZ thermostat kit Tudor
90423NZ overload kit Tudor
Spare
Parts