Tudor - Installation & Operating Instructions - 85807 - June 2012 v1.00

Read These Warnings First

Please read all installation requirements, installation procedures and precautions before 
installing any  Tudor water heater.

Never attempt to install any  Tudor water heater without reading all of the applicable 
instructions.

Tudor water heaters are open outlet (vented) water heaters and must not be installed in 
the same way as mains pressure type water heaters.

The outlet from any  Tudor water heater must be connected directly to an outlet spout on 
the sink and must not be obstructed by a tap or valve or in any other way. 

The water flow is controlled by a cold water tap connected before the water heater. Cold 
water pushes hot water out of the tank when the cold water tap is turned ON. Any such 
cold water tap should be labelled HOT.

This water heater must not be connected to more than one outlet.

All plumbing connections must be made in accordance with AS3500.

The heater is intended only for indoor use and should never be installed outdoors or be 
exposed to the elements of nature. 

Over-sink and under-sink models are NOT interchangeable.

Children should be supervised to ensure they do not play with the heater.

The heater is unsuited for use by children or infirm people without supervision. 

If the power supply cord is damaged it must be replaced by a  Service Provider or a 
qualified electrician. 

Do not remove the cover of the heater under any circumstances without first isolating the 
heater from the power supply.

Outlet temperature should never be set to less than 60°C without due regard to regulations 
governing the storage temperature of hot water. 

This unit must not be cleaned by a water jet.

Before installing, ensure that the following are available:

a) sufficient space to position the heater so there is 270 mm clear access under the heater 
(over-sink models) or 270mm above (under-sink).

b) standard 10 amp 240 volt power outlet within 1500 mm of the heater

c) cold water supply with a minimum working pressure of 50 kPa and a maximum working 
pressure of 350 kPa.

d) Isolating valve (not supplied)

If the pressure may exceed 350 kPa, a 350kPa pressure limiting valve (not supplied) must 
be installed in the cold water supply line.

A double check valve (not supplied) is required to comply with the backflow requirements 
of AS/NZS3500.1

Under-sink models must be installed beneath approved vented mixer taps requiring a 
single mounting point on a sink, basin or tub.

Water pressure under 100 kPa may be sufficient for over-sink heaters but may not operate 
under-sink mixer taps satisfactorily.

Installation Requirements

Summary of Contents for Tudor series

Page 1: ...k water heater 21101NZ Tudor 10 Litre over sink water heater 21102NZ Tudor 10 Litre under sink water heater 99006NZ Telescopic swivel arm only 99032NZ Telescopic Spout accessory for 21051NZ 21052NZ 99...

Page 2: ...eater The heater is unsuited for use by children or infirm people without supervision If the power supply cord is damaged it must be replaced by a Service Provider or a qualified electrician Do not re...

Page 3: ...th a WHITE band on it connects to the tap hole with NO marking 5 The hose with a RED band on it connects to the tap hole with a RED marking 6 The hose with a BLUE band on it connects to the tap hole w...

Page 4: ...must be accessible Do not turn the power ON until the heater is filled with water and air is purged from the heater Step Five Commissioning Fill the heater tank and purge air from the heater by turni...

Page 5: ...tall approved vented tapware see page 3 Tudor Heater Restrictaflow see page 4 265 5L 355 10L I I I I I I I E Tudor udor DEPTH 215 5L 265 10L WIDTH 255 5L 310 10L HEIGHT 390 5L 455 10L SIDE VIEW 100 14...

Page 6: ...r temperature could fall below 5 C when the heater is not in use the anti freeze setting on the temperature control will maintain stored water temperature over 5 C to prevent freezing and damage to th...

Page 7: ...t to the plastic upright 4 Pull the capillary out of the thermostat pocket located on the element assembly 5 Take the new thermostat 90421NZ and uncoil about half of the capillary tube 6 Push the new...

Page 8: ...establish date of installation should it become necessary to service the appliance under terms of the Zenith warranty To register your installation go to www zenithheaters co nz and look under the hea...

Reviews: