 Tudor - Installation & Operating Instructions - 85807 - June 2012 v1.00 

 

Page 3

NOTE:  Failure to correctly fit the Restrictaflow valve (provided) will void the warranty

Step One - Tapware

Note: Instructions for correct assembly and installation of Tudor tapware is included in 
the tapware box. Pay close attention to these instructions.

Over-sink models must be installed with an inlet valve to control the flow from the water 
supply to the heater. No valve is supplied with the heater. The water supply and valve should 
be connected after fastening the heater to the wall. 

Over-sink models are supplied with a 300 mm swivel spout. A 300 mm to 600 mm 
telescopic swivel spout (99006NZ) is available as an optional extra. 

Under-sink models must be installed with approved vented tapware. It is advisable to fit the 
tap to the sink before mounting the heater to the wall beneath the sink. 

1. Install the Restrictaflow valve provided, with the isolating valve (not supplied), into the 
main cold water supply line. The Restrictaflow is adjustable and must be set to deliver no 
more than 6Ltr/min (Max.) 

NOTE:

 Do not fit the Restrictaflow valve to the tank (See P.5 diag)

2. Flush water supply pipes thoroughly to remove any silt or fines. 

3. Fasten the tap body to the sink using the bolt & plate system provided. 

4. The hose with a WHITE band on it connects to the tap hole with NO marking.

5. The hose with a RED band on it connects to the tap hole with a RED marking.

6. The hose with a BLUE band on it connects to the tap hole with a BLUE marking.

7. Ensure that the flexible tubes are firmly attached to the base of the tap body and in the 
correct sequence. Refer tapware installation sheet. 

Do not dismantle the assembled tap body during installation. Mixer taps are factory tested 
and sealed to provide optimum performance.

To adjust water temperature delivered by Solo and Hero mixer taps, see instructions on page 
7.  Such adjustments should be made only by a qualified technician.

Step Two - Positioning

Over-sink heaters should be installed so that the outlet spout drains to a sink or tub, and 
with a clearance of 270 mm beneath the heater to allow for service access.

Under-sink heaters should be installed a closely as possible to directly below the outlet tap  
with a clearance of 270 mm above the heater. 

This unit must not be positioned in an area that may be cleaned by a water jet.

Step Three - Fastening

It is not necessary to remove the case of the heater during installation.

The heater must be wall mounted with two fixing screws as shown in the diagram on page 
5. Fixing screws must have the strength to support the filled heater. 

The fixing screws are to protrude 4 mm from the wall as shown in the diagram on page 5 so 
as to fit into keyhole slots provided on the rear of the heater.

Installation Procedure

Summary of Contents for Tudor series

Page 1: ...k water heater 21101NZ Tudor 10 Litre over sink water heater 21102NZ Tudor 10 Litre under sink water heater 99006NZ Telescopic swivel arm only 99032NZ Telescopic Spout accessory for 21051NZ 21052NZ 99...

Page 2: ...eater The heater is unsuited for use by children or infirm people without supervision If the power supply cord is damaged it must be replaced by a Service Provider or a qualified electrician Do not re...

Page 3: ...th a WHITE band on it connects to the tap hole with NO marking 5 The hose with a RED band on it connects to the tap hole with a RED marking 6 The hose with a BLUE band on it connects to the tap hole w...

Page 4: ...must be accessible Do not turn the power ON until the heater is filled with water and air is purged from the heater Step Five Commissioning Fill the heater tank and purge air from the heater by turni...

Page 5: ...tall approved vented tapware see page 3 Tudor Heater Restrictaflow see page 4 265 5L 355 10L I I I I I I I E Tudor udor DEPTH 215 5L 265 10L WIDTH 255 5L 310 10L HEIGHT 390 5L 455 10L SIDE VIEW 100 14...

Page 6: ...r temperature could fall below 5 C when the heater is not in use the anti freeze setting on the temperature control will maintain stored water temperature over 5 C to prevent freezing and damage to th...

Page 7: ...t to the plastic upright 4 Pull the capillary out of the thermostat pocket located on the element assembly 5 Take the new thermostat 90421NZ and uncoil about half of the capillary tube 6 Push the new...

Page 8: ...establish date of installation should it become necessary to service the appliance under terms of the Zenith warranty To register your installation go to www zenithheaters co nz and look under the hea...

Reviews: