802149NZ - BHA; CHA; CSHA -Installation Instructions - Aug 2015 - V2.00
If an external filter is installed, select position B
B
Rotate 90°
only
1
2
3
4
Check the table below to determine which filter bypass position you need for your product.
Note:
Before you install a unit, determine whether a water softener or an external filter is required.
4.3
E
xternal Bypass Valve
The diverter bypass valve allows the user to choose to have the boiling feed water bypass the internal filter and
only be filtered by the external filtration. This diverter valve is located at the rear panel of the Zenith HydroTap
undersink unit, see the image below.
If no external fi lter is installed, select position A
A
Rotate 90°
only
1
2
3
4
BHA Installation
NO EXTERNAL
FILTER INSTALLED
SELECT POSITION A
EXTERNAL
FILTER INSTALLED
SELECT POSITION B
B
1
2
3
4
A
1
2
3
4
PN: 801231