background image

TINY Series

Water Engineering Corporation

Long Beach, CA U.S.A

1 (888) 675-5187

[email protected]

WECO 

Reverse Osmosis 
Drinking Water Filter 
System Manual

www.wecofilters.com

Summary of Contents for TINY Series

Page 1: ...TINY Series Water Engineering Corporation Long Beach CA U S A 1 888 675 5187 sales wecofilters com WECO Reverse Osmosis Drinking Water Filter System Manual www wecofilters com ...

Page 2: ...ith the water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after system System must be installed indoor It is recommended that installation of the water filter be done by a professional plumber Important 1 TINY SET 2 It is recommended to change the 2 pre filters at least every 3 5 months It is advised to change them on time to avoid any damages to ...

Page 3: ...ge MAIN SUPPLY WATER FILTERED WATER BRINE Feed Water IN OUT Product Water Flow Restrictor Check Valve INLET Water supply adapter valve Cold water shut off valve Auxiliary faucet Garbage disposal Carbon Filters Drain Saddle Storage tank with valve in open Position Sediment Filter Membrane Inline GAC Filter Alkaline UV Filter optional A B C D A E F G H I J A K A B C D E F G H I J K Reverse Osmosis S...

Page 4: ...EMS ONLY 5th Stage Filter PRODUCT WATER TANK 4th Stage Filter 2nd Stage 1st Stage MAIN SUPPLY WATER FILTERED WATER BRINE Feed Water Product Water INLET Low Pressure Switch Inlet Water Solenoid Valve High Pressure Switch Flow Restrictor Check Valve A B C D E F G H I J K A B C D F G H I J K E Reverse Osmosis System Electric Booster Pump Tubing Diagram Electrical Diagram Fig 2 Fig 3 TINY Manual 2017 ...

Page 5: ... OUT Product Water Flow Restrictor Check Valve INLET INLET BRINE IN Water supply adapter valve Cold water shut off valve Auxiliary faucet Garbage disposal Carbon Filters Drain Saddle Storage tank with valve in open Position Sediment Filter Membrane Inline GAC Filter Alkaline UV Filter optional Permeate Pump L L Reverse Osmosis System Electric Diagram with Permeate Pump Fig 4 A B C D A E F G H I J ...

Page 6: ... Metal chips will stain Porcelain 5 NOTE The drinking water system must be connected to the COLD water supply only 1 Turn off the cold water supply to the sink faucet by locating the Round or oblong handle on the right side of the sink cabinet and Turning clockwise until the water supply is off NOTE If the cold water shut off valve fails to turn off the water the house water supply can be turned o...

Page 7: ...t onto sink with the stem going through the hole 2 Place metal washer and lock washer over threaded stem of faucet and tighten nut from under the counter surface to lock the faucet into place DO NOT OVER TIGHTEN 3 Connect the blue tube to the faucet stem under the counter and tighten Fig 6 2 Mark the hole position on the pipe and drill a hole through one side of the pipe Fig 8 Fig 7 Fig 8 Chrome W...

Page 8: ...o drain pipe and tighten the two screws evenly Fig 9 NOTE The center hole on the sponge must be removed 4 Connect the Black tubing to the drain clamp Fig 9 CONNECTING THE SYSTEM Use the color coded tubing to make the following connections The white tubing connects the water supply adapter to the inlet side The blue tubing connects the faucet to the outlet side The Black tubing connects to the drai...

Page 9: ... is normal as the contaminated water is being rejected by the reverse osmosis membrane 8 START UP PROCEDURE DO NOT DRINK THE WATER FROM THE FIRST TANK PRODUCED BY THE SYSTEM DISCHARGE THE WATER FROM THE STORAGE TANK BY OPENING THE FAUCET DISCHARGING MIGHT TAKE UP TO 15 MINUTES If you have any difficulties with the installation or require additional information on your unit please consult with our ...

Page 10: ... Thin Film Composite membrane should last between 2 to 4 years depending on the quality of your local water Drain your storage tank twice each month to extend the membrane and have the freshest water in the storage tank Drain the storage tank by lifting the faucet handle into the parallel position with the spigot until water flow stops from the tank Return the faucet handle to the closed position ...

Page 11: ...ning the saddle valve on the water supply adapter clockwise until it stops 2 Close the storage tank ball valve by turning the handle perpendicular to the valve body 3 Open the drinking water faucet relive pressure 4 Allow 3 5 minutes for pressure in the system to drop 5 Disconnect the tubing from the membrane cap by pushing in and holding down the end collar ring surrounding the quick connect elbo...

Page 12: ...pport staff Phone 1 888 675 5187 Email sales wecofilters com Water Engineering Corporation 1037 Stanley Ave Long Beach CA 90804 USA CUSTOMER SATISFACTION IS OF PRIMARY CONCERN PLEASE CALL IN THE EVENT THERE IS A SERVICE PROBLEM Notice Your RO system has been thoroughly tested and inspected for production rejection leaks and shut off functions at our factory Therefore it might have some water in it...

Page 13: ...12 TINY Manual 2017 Water Engineering Corporation This page is intentionally left blank ...

Page 14: ...WECO TINY Series Reverse Osmosis Drinking Water Filter System Manual Water Engineering Corporation Long Beach CA U S A 1 888 675 5187 sales wecofilters com WECO www wecofilters com ...

Reviews: