User’s Manual
18
ZEKA LP
7. DETAILED COMMAND DESCRIPTION
7.1. SETTING PRINTER OPERATION MODE
7.1.1. SET PRINT DENSITY
Adjust the print density according to information and paper characteristics.
Format:
Dn
n
values varies from 0 to 15, as 15 responds to maximum density. Higher
printing density can cause slower printing.
Example
:
D8
Sets print density 8.
7.1.2. SELECT CODE TABLE
ZEKA LP
supports 3 code tables. Symbols with ASCII codes from 0 to 31 don’t
have images.
Format:
In
n=0
CP-1251 – Windows - English
n=1
DOS – Cyrillic - Bulgarian
n=2
CP-1251 – Windows - Bulgarian
Example
:
I0
Set Windows - English characters.
7.1.3. SET PAGE LENGHT
Format:
Qm,n
m
is the length of the printable area. Allowed value is up to 1200 dots (150
mm).
n
is the added space after printing. Allowed value is up to 255 (32 mm).
When printing on continuous paper both vertical length and added space
must be set. The size is in dots (8 dots/mm or 203 dots/inch). If the generated
by the printer image has parts that are out of the limits, they will be partly or
completely cut.
Example
:
Q240,8
Page length 30 mm and space 1 mm.