Adjustment of the light source infinitely .................................... 6-12 V
Degree of protection ................................................. IP ...................... 20
Electrical safety ................................................ ....... according to IEC 348-78 and VDE 0411
Radio interference (limits according to class B) .................. VDE 0875
Stage
Cross table ................................................. ............... 50 x 30 mm
Table position ................................................. ........... read with verniers
Table rotation ................................................. 90 ° ..........
Table insert panels
Outside diameter 132 mm inner diameter ............................. 40, 50, 70 mm
Outside diameter 56 mm, inner diameter ............................. 10, 20, 27 mm
Table load capacity ................................................. sample weight ≤ 5 kg ...
Object focus
Coarse feed ................................................. ................. 4 mm
Fine drive ................................................. .................. in the area of the coarse adjustment knob
Scaling ................................................. ............... in 1-micron intervals
Automatic exposure control ............................................ switchable between the integrated cameras
For 24 x 36 mm or
Large format 4x5 "/ 9 x 12 cm
Setting the automatic exposure ......................... ISO 6/9 '- 5000/38'
(ASA 6-5000) (DIN 9-38 ')
Page 22
1.2.4
Optical data
Standard lenses for brightfield illumination .................. Planachromat 5x / 0.1 ∞ / - (14.90) *)
Plan Achromat 10x / 0.2 ∞ / - (13,90) *)
Plan Achromat 20x / 0.4 ∞ / 0 (2.60) *)
Plan Achromat 50x / 0.8 ∞ / 0 (0.46) *)
Standard lenses for Hell-/Dunkelfeldbeleuchtung .... Planachromat 5x / 0.1 ∞ / - HD (2.80) *)
Plan Achromat 10x / 0.2 ∞ / - HD (12,00) *)
Plan Achromat 20x / 0.4 ∞ / 0 HD (2.65) *)
Plan Achromat 50x / 0.8 ∞ / 0 HD (0.50) *)
*) Working distance (minimum value in mm)
Lens changes ................................................. manually .......... 5x nosepiece
Display of the selected objective ............................... via LED display in the control panel
Eyepieces
resistant design .............................................. GF- Pw 10x (25) Br10
adjustable version ........................................ GF-Pw 10x (25) Br10
Apparent field of view ........................................ Ø 250 mm
Magnification ranges in the visual insight
Standard equipment ......................................... 50 - to 500-fold
Additional Equipment ............................................. of 16 - to 2500-fold
Photomicrographs magnifications (format 9x12 cm)
Standard equipment ......................................... from 50:1 to 500:1
Additional Equipment ............................................. 25:1 up to 1600:1
Summary of Contents for JENA PLAN HD 9x12
Page 2: ...Original text Page 1 Contribute a better translation Operation instructions JENA PLAN...
Page 9: ...B 0705 1 01 1992 Digitized 07 2005 VI OVERALL VIEW Page 9...
Page 14: ...B 0705 1 01 1992 Digitized 07 2005 1 2 Figure 1 1 microscope equipment JENA PLAN Page 14...
Page 15: ...B 0705 1 01 1992 Digitized 07 2005 1 3 Page 15...
Page 17: ...B 0705 1 01 1992 Digitized 07 2005 1 5 Page 17...
Page 18: ...B 0705 1 01 1992 Digitized 07 2005 1 6 Page 18...
Page 19: ...B 0705 1 01 1992 Digitized 07 2005 1 7 Page 19...
Page 20: ...B 0705 1 01 1992 Digitized 07 2005 1 8 Page 20...
Page 33: ...Page 33 B 0705 1 01 1992 Digitized 07 2005 1 22...
Page 67: ...B 0705 1 01 1992 Digitized 07 2005 2 35 Page 69 3 Care Maintenance Service 3 1 Care...