35
4.4
Visualization of fault notifications
The unit control system is equipped with an internal system for recognizing faults. A fault notification is visualized through the
flashing of the red “Fault LED” and a coded failure prediction using LED1-4. As a reaction to a fault status, the fans are shut down
and the supply and exhaust valves are automatically closed.
4.4.1
Fault codes in the fault status
Fault
LED1
LED2
LED3
LED4
Fan 1
flashes
-
-
flashes
Fan 2
-
flashes
-
flashes
Temp. sensor outdoor air
-
-
flashes
flashes
Servo 1
flashes
-
flashes
flashes
Servo 2
-
flashes
flashes
flashes
Humidity sensor
flashes
flashes
-
flashes
CO
2
/ VOC sensor
-
-
-
flashes
Should a fault notification occur, note the type label serial number, and please contact a responsible installation technician.
4.5
Technical description
General specifications
Description / Value
Heat exchanger type
Enthalpy exchanger with polymer membrane
Housing / Interior lining
Aluminum, power-coated, free of thermal bridges, interior lining
is made of expanded polypropylene (EPP) to provide heat and
sound insulation
Duct connection diameter
4" (100 mm)
Weight
59 lbs. (22 kg)
Electrical connection
110 or 220 VAC, 50-60 Hz
Rated current
0.15 A
Protection class
II
Degree of protection
IP 20
Temperature ranges
-4°F to 104°F (-20°C to 40°C)
Installation location
Inner side of vertical outer wall; wall thickness 10-13/16” min.
to 23-5/8” max. (275 mm min. to 600 mm max.)
Mounting position
Wall-mounted, supply air and exhaust air aperture at top
Operation data
Fan speed
Volume flow
[cfm] / [m
3
/h]
Thermal efficiency
[%]
Humidity efficiency
[%]
Power consumption
[W]
Standby
-
-
-
< 1
FS1
10 / 15
90
84
4
FS2
15 / 25
83
73
5
FS3
25 / 40
76
61
9
FS4
35 / 60
71
54
17