12 - EN
Menu P5
¨
Setting additional programmes
Additional programme values
Submenu
Description
Minimum
Maximum
General Reset
P50
Activation of the open fire programme.
0 (= No)
1 (= Yes)
0
P51
n/a
0 (= No)
1 (= Yes)
0
Leave the value at '0'.;
P52
n/a
0
3
2
P54
Confirming the presence of a bypass.
0 (= No)
1 (= Yes)
1
The standard ComfoAir configuration includes a bypass. Therefore, leave the value at ‘1’.
P56
Setting the required air volume in the house.
■
nL: ”normal air volume”.
■
HL: "high air volume".
nL
HL
HL
Setting the air volume is the starting point for programming the air specifications and setting the fans.
P57
Setting the ComfoAir type.
■
Li = ”Left-hand version”.
■
Re = ”Right-hand version”.
Li
Re
Li
With delivery the ComfoAir is correctly pre-programmed at the factory.
After an general reset the pre-programming is lost and the setting must be reset.
The right setting is mentioned on the identification plate on the side of the ComfoAir.
P58
n/a
0
1
0
P59
Confirming the presence of an enthalpy exchanger.
■
0; Enthalpy exchanger not fitted
■
1; Enthalpy exchanger with RH sensor.
■
2; Enthalpy exchanger without RH sensor.
0 (= No)
2 (= Yes)
0
Ensure the condensation drain is sealed.
If an enthalpy exchanger without a sensor is selected, then the safety programme will not be activated and
malfunction alerts EA1 & EA2 will never occur.
Menu P6
¨
Setting additional programmes
Temperature values
Submenu
Description
Minimum
Maximum
General
Reset
P60
n/a
0 (= No)
3 (= Yes)
0