ZyPer4K-M
User Manual Revision 2.5
Physical and Environmental
The following parameters apply to all encoders and decoders unless specifically stated
otherwise.
Type
Parameter
A/C Adapter
100-1240VAC 50-60Hz 0.7-0.45A draw on AC Mains
Output Max: 12VDC 2.5A
ZyPer4K-M unit power
consumption
12VDC at 1.2A max 12W nominal (Encoder without extended media option)
12VDC at 1.6A max 16W nominal (Encoder with extended media option)
12VDC at 1.2A max 12W nominal (Decoder)
Dimensions (LxWxH)
maximum envelope
163mm x 175mm** x 43mm* (Decoder or Encoder with no extended input
option)
166mm x 228mm** x 43mm* (Encoder with extended input option)
*subtract 6mm from height if rubber feet are removed
** add 48mm to overall width if both mounting ears are installed
Weight
880g (Decoder, Encoder with no extended input option)
1070g (Encoder with extended input option)
Operating Temperature
0° C to +45° C (32° F to 113° F)
Non-Operating Temp
-20° C to +80° C (-4° F to +176° F)
Operating Altitude
3,000M (10,000ft)
Non-Operating Altitude
10,500M (35,000ft)
Humidity (op/storage)
20% to 90% (Non-Condensing)
Coating
White, satin anti-microbial powder coat
Certifications
IEC 60601-1: 1988 + A1:1991 + A2: 1995, IEC 60601-1-1, IEC 60601-1-2, IEC
60601-1-4, UL 60601-1, 1st Edition : 2006, CAN/CSA-C22.2 No. 601.1-M90:
2005,IEC 60601-1: 2005, IEC 60601-1–2: 2006, ANSI/AAMI ES 60601-1:
2005, CAN/CSA-C22.2 No 60601.1-08, EN 60601–1: 2006, EN 60601-1–2:
2007, CE (MDD) Annex I, essential requirements of MDD 93/42/EEC, version
2007, IEC60950-1, 2nd edition: 2005, UL94 on Test flammability of plastic
materials for parts in devices and appliances.
User Manual
Page
of
51
53