3)
Connect the cables according to the table below.
Pin RJ45
Cable colour
Connection
24-pin terminal block
4
Blue
CAN-H
7
5
White-blue
CAN-L
8
Table 7 - CAN bus connections
4)
Connect other wallboxes in daisy-chain using RJ45 connectors through the CAN ports.
Consult the manual of the charging station to check the firmware
version installed. If it is lower than version 1.0.493, please contact
Azzurro technical support at the toll free number 800727464
Note
4.3.
Connecting to Azzurro photovoltaic or storage inverters
Up to 8 Azzurro photovoltaic or storage inverters can be connected in cascade. Connect the
Connext system to the first inverter according to the instructions given here. To connect to hybrid,
storage or photovoltaic inverters, follow the instructions in the sections below.
NOTE: IF ON THE SYSTEM THERE IS ONE OF THE FOLLOWING INVERTERS, 1PH HYD3000-
HYD6000-ZSS, 3PH HYD5000-HYD20000-ZSS, 3000SP, REFER TO THE RESPECTIVE MANUALS
FOR THE SENSOR CONNECTION (ZSM-ACC-TA) AND / OR THE METER (DTSU666).
4.3.1.
Connecting to 1-phase Azzurro hybrid inverters
To connect the RS485 port to HYD-3000/3600/4000/5000/6000-ES inverters, follow these
instructions.
1)
Remove a suitable length of the protective sleeve, as shown in figure (A: 80~100 mm B: 6~8
mm).