For safety reasons, ZCS and/or its authorised partners may not perform repair/maintenance work
or move the chargers from and to the ground if they are installed at a height of more than 180 cm.
Stations installed at higher heights must be moved to the ground before they can be repaired or
serviced.
3.3.
Materials and cables
Name
Specifications
Quantity
Power cord
≥ 3 × 1.5mm
2
single-phase
As required
Network cable
STP, CAT5E, 8 cores
As required
Connector for network cable
RJ45
As required
Insulating tape
0.15 mm × 18mm; 0-600V;
0°C-80°C
As required
Cable tie
4 × 200mm
As required
Table 6 - Electrical equipment
It is important that all cables used are suitable for outdoor use.
NOTE:
For safety reasons, make sure to use suitably sized cables, otherwise the current may cause
overheating or overloading, which could result in a fire.