8.2 PYLONTECH BATTERIES IN PARALLEL
9.6.1 SINGLE WECO 5K3XP BATTERY
3.1 Battery connection
Maximum DoD
programmable
90%
DO NOT CHANGE DIP
SWITCH POSITION WITH
THE BATTERY ON!!
OFF
Communication cable pinout between WeCo
battery and Inverter, from left to right
PIN 1:
CAN (White-Orange)
PIN 2:
CAN (Orange)
PIN 1:
White-Orange
PIN 2:
Orange
PIN 3:
White-Green
PIN 4:
Blue
PIN 5:
White-Blue
PIN 6:
Green
PIN 7:
White-Brown
PIN 8:
Brown
WeCo
Inverter
The communication cable is located
inside the kit in the inverter box.
Communication connections between batteries and inverter:
•
CAN-A of
Master Battery
COM Port of
inverter
ATTENTION! This battery is usually
used for three-phase hybrid
inverters (HYD 3PH).
If used with
this inverter the communication and
power cables between the batteries
must be ordered separately.
Attention:
When connecting 5k3XP batteries to single-phase hybrid inverters (HYD 1PH),
only the LOW VOLTAGE
section must be used.
To prevent damage to the batteries and/or inverters, do not use the high voltage section.
LOW VOLTAGE
CONNECTION
CONNECTION
HIGH VOLTAGE
COM
GND
PWR
+/-
In case of a SINGLE BATTERY:
1. Connect the
CAN-A
input
2. Set DIP Switches
3. Connect the power cables with
the appropriate B+ and B- connectors to the
corresponding input (as shown in the figure).
4. Connect the ground
cable to the battery