3.1 Battery connection
The communication cable is located
inside the kit in the inverter box.
Maximum DoD
programmable
90%
10.2.1 SINGLE AZZURRO ZSX 5000 PRO BATTERY
3.3 Grid Connections
Communication connections between batteries and inverter:
•
CAN of
Master Battery
COM Port of
inverter
Communication cable pinout between
Azzurro battery and Inverter, from left to right
PIN 1:
CAN H (blue wire)
PIN 2:
CAN L (white-blue
wire)
PIN 1:
White-Orange
PIN 2:
Orange
PIN 3:
White-Green
PIN 4:
Blue
PIN 5:
White-Blue
PIN 6:
Green
PIN 7:
White-Brown
PIN 8:
Brown
Azzurro
Inverter
In case of multiple batteries connected in
parallel or when adding new batteries
to a
system with batteries already installed,
make
sure that the difference between the voltages of
all the batteries is less than 0.5 Volt
. Each
battery must be measured individually, so make
sure the batteries are not connected to each
other. Contact technical support if the voltage
between the batteries is not aligned.
In case of a SINGLE BATTERY:
1. Connect the
CAN
input
2. Make the power connections
by connecting the appropriate
P+ and P- connectors to the
corresponding input (as shown
in the figure).
3. Connect the ground cable to
the battery
4. Press the front part of the
battery to switch it on.
COM
GND
POWER +/-