Secti on 4 -
INSTALLATION
Zator Srl
Via Galvani 11 - 20095 - Cusano Milanino (MI) - Italy
www.zator.it - [email protected]
27
4.6
Valve acti vati on
The MZS valve must be controlled by two solenoid valves, one fi tt ed on the valve and a second one
external*:
•
Solenoid valve fi tt ed on the valve for the
drive air
;
•
2/2 way external solenoid valve for the
nebulizati on air
.
The drive pressure must be minimun 5 bar.
The nebulizati on pressure must be between 0,5÷5 bar.
The
nebulizati on air
must be
acti vated before
and
deacti vated aft er
the
drive air
to avoid that the glue
can dirty the nozzle and the air cap.
OFF
OFF
OFF
OFF
ON
TIME
NEBULIZATION AIR
DRIVE AIR
ON
*Parts are supplied separately