USER AND MAINTENANCE MANUAL
PNEUMATIC SPRAY VALVE
MZS
26
4.5
Installati on diagram
Drive air:
Connect a pipe Ø6x4 to
the air connecti on on
the valve. The drive air
pressure must be 5 bar.
Nebulizati on air:
Connect a pipe Ø6x4 (from
the 2/2 way external solenoid
valve*) to the air connecti on
on the valve. The nebulizati on
air pressure must be between
0,5 and 5 bar
(by an external
air pressure regulator*)
.
Fluid inlet:
Connect a
pipe
* by the
use of
G1/8”
Provide for all connecti ons a pipes length such as to ensure a good accessibility to the valve to be able
to easily carry out the operati ons of maintenance and cleaning.
The required connecti ons for the functi oning of the MZS valve are:
2
1
3
4.4
Drive air connecti on and nebulizati on
Connect a
pipe
Ø
6x4
to the air connecti on on the
valve. The drive air pressure must be 5 bar.
Connect a
pipe
Ø
6x4
to the air connecti on on
the valve. The nebulizati on air pressure must be
between 0,5 and 5 bar.
1. Drive air
connecti on
2. Nebulizati on
air connecti on
1
2
*Parts are supplied separately