Secti on 6 -
MAINTENANCE
Zator Srl
Via Galvani 11 - 20095 - Cusano Milanino (MI) - Italy
www.zator.it - [email protected]
37
Screw* the
adjustment block
in the
valve body with a 17mm wrench;
6
*Pay att enti on
that the adjustment block is not ti lted
during the screwing to avoid damage to the thread.
Screw** the
nozzle
with a 6mm
wrench;
7
**Before screwing the nozzle,
check that the micrometric
adjustment handle is completely loosened to avoid damage to
the nozzle and needle. To loosen the micrometric adjustment
handle, turn it counter-clockwise unti l it doesn’t resist anymore.
Screw the
air connecti ons
with a
11mm and 9mm wrench;
5
11
9
!
NO
SI
17