2.6
Use of adhesives, glues or other fl uids
The use of the valve with adhesives, glues or general fl uids must be respect the following basic rules.
Before use
a specifi c type of fl uid check that:
•
The fl uid viscosity is compati ble with the features of the valve
•
The characteristi cs of the fl uid meet the desired requirements
•
The datasheet of the fl uid provided by the manufacturer includes all the informati ons about the
fl uid such as: viscosity, applicati ons, gluing ti me (for glues or adhesives) and storage
•
The storage ti me of the fl uid has not been exceeded
•
The fl uid has not been exposed to temperatures near or below than zero therefore it has
deteriorated
•
The packaging of the fl uid are sealed
For the use of
special adhesives, glues or fl uids
we recommend to contact the Zator company to
verify the compati bility of the applicati on.
Before use a diff erent type of fl uid clean accurately the valve to avoid possible contaminati on of the
new fl uid.
When used water-based adhesives of glues they are easily removable with water in their liquid state.
However, when they harden is more diffi cult to remove it. For this reason, before long stop it is
recommended to wash accurately the valve. Please refer to the maintenance program shown in this
manual.
Summary of Contents for MZF
Page 1: ...MZF PNEUMATIC SPRAY VALVE USER AND MAINTENANCE MANUAL...
Page 6: ......
Page 7: ...USER AND MAINTENANCE MANUAL PNEUMATIC SPRAY VALVE MZF...
Page 45: ...MZS1XXSFRM 12 21 77 34 11 8 70 M5 111 46 22 109 128 G1 8 15 31 6 23 34 6 8 14 6 18 22 35...
Page 46: ...NOTES 46 PNEUMATIC SPRAY VALVE MZS...
Page 47: ......