SECTION 6 - MAINTENANCE
29
Zator
Via Galvani, 11 - 20095 - Cusano Milanino (MI) - Italy
www.zator.it - [email protected]
9
10
13
Compressed
spring
4
5
6
7
Unscrew the nozzle with a 10mm wrench;
Loosen the needle adjustment whit the micrometric
adjustment handle (see section 5.2 - Needle travel
adjustment), by turning it counter-clockwise until it doesn’t
resist anymore;
Unscrew the air connection with a 9mm wrench;
Unscrew the adjustment block with a 13mm wrench, being
careful of the inner compressed spring;