SECTION 4 - INSTALLATION
23
Zator
Via Galvani, 11 - 20095 - Cusano Milanino (MI) - Italy
www.zator.it - [email protected]
*Parts are supplied separately
*Parts are supplied separately
TILT TO FOLLOW
Direction on travel
The contact gluing application is used when is necessary to dispense very thin glue lines.
In this case the valve must always be positioned vertically, with the nozzle facing downwards but with
an inclination of 7 ÷ 8° with respect to its axis towards the direction of travel and the nozzle must lightly
touch the surface to be glued.
7 ÷ 8°
7 ÷ 8°
4.3
Contact gluing application
4.4
Fluid supply connection
4.5
Electrical connection
Fluid supply connection
G1/8”
Electrical
connection
The valve must be connected to a glue feed units*.
A flexible plastic pipe* (for applications up to 8 bar)
must be connected to a pipe fitting (G1/8”)* to be
screwed on the fluid supply connection of the valve.
For applications with working pressure over 8 bar use
fittings and pipes* for high pressure must be used.
Connect an electrical cable* with cross-section not
less than 0.35 mm to the solenoid valve connector.