Page - 30/54
AFDZP0BA – VCM Zapi 2uC - User Manual
signaled.
17) TRANSFER HOURS
Three levels are available:
LEVEL 0
= if there is a mismatch between Hour meter of traction and VCM,
an alarm is signalled and the higher value is store on both after 2 min.
LEVEL 1
= if there is a mismatch between Hour meter of traction and VCM,
an alarm is signalled and the value present on the traction is stored in the
VCM
LEVEL 2
= if there is a mismatch between Hour meter of traction and VCM,
an alarm is signalled and the value present in the VCM is stored in the
traction
18) ENC. LOCK TEST
It enables the diagnoses of “encoder locked” for the encoder 1 and the
encoder 2. In case of encoder locked an alarm is signaled and the pump is
stopped.
Menu “Adjustments”
3) SET BATTERY TYPE
It selects the nominal battery voltage.
4) ADJUST
BATTERY
Fine adjustment of the battery voltage measured by the controller.
5) BAT. MIN ADJ.
It adjusts the lower level of the battery discharge table. It is used to calibrate
the discharge algorithm with the battery of the application. See chapter 9.6
for more information.
6) BAT MAX ADJ.
It adjusts the upper level of the battery discharge table. It is used to calibrate
the discharge algorithm with the battery of the application. See chapter 9.6
for more information.
7) ENC1 SENS 100MM
It defines the sensibility of encoder 1 expressed in number of pulses/100mm.
8) ENC2 SENS 100MM
It defines the sensibility of encoder 2 expressed in number of pulses/100mm.
9) WATCH
YEAR
It permits to set the year of the Real Time Clock.
10) WATCH MONTH
It permits to set the month of the Real Time Clock.
11) WATCH DATE
It permits to set the date of the Real Time Clock.
12) WATCH HOURS