5.Technical Data

Gas Burners Rating

Rapid Burner (big)

2,8 kW (G30/G31) - 3 kW (G20)

Semirapid Burner (medium)

2 kW

Auxiliary Burner (small)

1 kW

Category

II 2H 3+

Setting

Natural Gas 20 mbar

Gas connection

G 1/2"

Electric Supply

230 V  50 Hz

HOB RECESS
DIMENSIONS

Length

550 mm.

Width

470 mm.

6.Instruction for the Installer

l

The following instructions about installation and

maintenance  must  be  carried  out  by  qualified

personnel in compliance with the regulation in

force.

l

The side walls of the unit in which the hob is

going to be installed, must not exceed the height

of the working top.

l

Avoid installing the appliance in the proximity of

inflammable materials (e.g. curtains, tea towels

etc.).

l

The appliance must be electrically disconnected

before all interventions. If any electric supply to

the appliance is required to carry out the work,

ensure all the necessary precautions are followed.

GAS CONNECTION

Choose  fixed  connections  or  use  a  flexible  pipe  in

stainless steel.

If using flexible metallic pipes, be careful they do not

come  in  contact  with  mobile  parts  or  they  are  not

squeezed.  Use  the  same  attention  when  the  hob  is

combinated with an oven.

IMPORTANT  - 

 To ensure a correct operation, a saving

of energy and the long-life of the appliance, the voltage

pressure  of  the  appliance  must  correspond  to  the

recommended values.

The adjustable connection is fixed to the comprehensive

ramp by means of a threaded nut GJ 1/2". Interpose the

sealing between the components as shown in fig. 3.

Screw the parts without forcing, adjust the connection in

the required direction and tighten everything.

IMPORTANT

  -  When  the  final  connection  has  been

made, it is essential that a thorough leak test is carried

out on the hob and installation. Use some soapy water,

never a flame.

A) Ramp with ending nut

B) Seal

C) Adjustable connection

Fig. 3

FO 0264

Summary of Contents for ZGLR 646

Page 1: ...GAS HOBS ZGLR 646 OPERATING AND INSTALLATION MANUAL IT ...

Page 2: ...sequent modifications During Operation About Installation Cleaning and Manteinance It is mandatory that all operations required for the installationarecarriedoutbyaqualifiedorcompetent person in accordance with existing rules and regulations Disconnect the appliance from the electrical supply before carrying out any cleaning or manteinance work Ensure a good ventilation around the appliance A poor...

Page 3: ... Fig 1 lett B are in the correct position To put the flame out turn the knob to the symbol l Always turn the flame down or put it out before taking the pans off the burner USINGTHEHOBCORRECTLY To ensure maximum burner efficiency it is strongly recommendedthatyouuseonlypotsandpanswithaflat bottomfittingthesizeoftheburnerused sothatflamewill notspreadbeyondthebottomofthevessel seethetable beside It ...

Page 4: ...GENERAL CLEANING Wash the enamelled components with warm soapy water Never use abrasive cleaners Frequently wash the caps and the crowns with hot soapy water carefully taking away any built up of food If the marks are particularly difficult to remove use common non abrasive cleaners or specific products Never use steel wool pads or acids AUTOMATIC IGNITION The automatic ignition of the gas burners...

Page 5: ... required to carry out the work ensureallthenecessaryprecautionsarefollowed GAS CONNECTION Choose fixed connections or use a flexible pipe in stainless steel If using flexible metallic pipes be careful they do not come in contact with mobile parts or they are not squeezed Use the same attention when the hob is combinatedwithanoven IMPORTANT To ensure a correct operation a saving of energy and the ...

Page 6: ...s necessary that you install a double pole switch between the appliance and the electricity supply with a minimum gap of 3 mm between the switch contacts and ofatypesuitablefortherequiredloadincompliancewith the current rules Theearthcable yellow green mustnotbeinterruptedby theinterrupter The connection cable has to be placed in order that in each part it cannot reach a temperature of 50 C higher...

Page 7: ...as pressure be different or variable compared with the required pressure an appropriate pressure adjuster for non LPG must be fitted on the gas supply pipe in compliance with the rules in force 8 Adaptation to different types of gas Fig 5 FO 0392 TYPE TYPE OF INJECTORS NOMINAL REDUCED NOMINAL NOMINAL OF GAS BURNER MARKS POWER POWER POWER PRESSURE 1 100 mm INPUT kW mbar KW m 3 h g h Rapid large 119...

Page 8: ... 6 10 If changing from natural gas to LPG completely tighten clockwise the screw until a small regular flame is obtained Finally check the flame does not go out when quickly turning the knob from the maximum position to the minimum position Thisprocedurecaneasilybecarriedout anyhowthehob has been positioned or built in the working top a a FO 0239 FO 1045 a FO 2100 FO 0757 FO 0735 Fig 6 Fig 7 Fig 8...

Page 9: ...t out as shown in Fig 16 taking care that the sealings meet without overlapping placethehobinthecutout takingcareofitscentring fix the hob with the relevant screws Fig 13 The traction of the screws is able to trace the sealing any excess of which can then be easily removed The edge of the hob forms a double labyrinth seal which provides a total guarantee against infiltration of liquids 9 Building ...

Page 10: ...hen unit with oven The hob recess dimensions must comply the indication given in Figs 15 and 18 and must be provided with brackets to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 16 e 17 The hob s electric connection and the oven s one must be carried out separately both for safety reasons and to allow the oven to be easily taken off t...

Page 11: ...11 ...

Page 12: ...35673 2101 01 00 Grafiche MDM Forlì ...

Reviews: