6
The appliance is designed to be connected to 230 V
monophase electricity supply.
The connection must be carried out in compliance with
the laws and regulations in force.
Before the appliance is connected:
1) check that the main fuse and the domestic installation
can support the load (see the rating label);
2) check that the power supply is properly earthed in
compliance with the current rules;
3) check the socket or the double pole switch used for
the electrical connection can be easily reached with
the appliance built in the forniture unit.
Connect the plug, able to support the load marked on the
identification plate, to the cable, following the
recommendation given in Fig. 4. The plug has to be fitted
in a proper socket.
If connecting the appliance directly to the electric system,
it is necessary that you install a double pole switch
between the appliance and the electricity supply, with a
minimum gap of 3 mm. between the switch contacts and
of a type suitable for the required load in compliance with
the current rules.
The earth cable (yellow/green) must not be interrupted by
the interrupter.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature of 50 °C higher
than the room temperature.
The brown coloured phase cable (fitted in the terminal
block contact marked with "L") must always be connected
to the network phase.
REPLACEMENT OF THE VOLTAGE CABLE
Only cable type H05 RR-F must be used. The cable
section must be suitable to the voltage and the working
temperature.
The yellow/green earth wire must be approximately 2
cm. longer than the phase wires (Fig 4).
After connection try out the heating elements allowing
them to function for approximately 3 minutes.
7.Electrical Connection
Fig. 4
FO 0073
Neutral
Earth (yellow/green)