4. INSTALLATION
10
SYNTHESIS GAS
Install the appliance in a dry and easily accessible place both to facilitate
its use and to carry out cleaning and maintenance.
The appliance must be installed at least 20cm from the walls of
the room or from other equipment so that the ventilation outlets
located on the sides of the oven are not obstructed.
Whilst in operation, cooking equipment produces vapor and cooking
smells that compromise the integrity of a healthy working environment.
In the case of gas ovens see paragraph 4.8.
A check must be made to ensure that the temperature and relative
humidity never exceed the maximum and minimum values indicted in the
specifications (see Enclosure A) even when the machine or other
machines in the room are functioning.
Exceeding these values especially the temperature or the maximum
relative humidity can easily and unexpectedly damage electrical equipment
creating hazardous situations.
4.2.1.
Location specifications for the installation of gas ovens
It is the installer’s responsibility to check that the gas system
of the room in which the oven will be installed is working properly
and that the ventilation and aeration conduits of this room function as
required for the total nominal heat input.
The Manufacturer cannot answer for damage caused by failure
to observe the norms in force for the installation of gas equipment.
During the installation, care must be taken to avoid obstructing the
cooling vents and the air intakes for combustion air built into the oven.
When dealing with gas equipment, the room in which it will be installed
must be sufficiently ventilated and aerated. To ensure this, the enclosed
area in which it will be housed must have at least two permanent apertures
leading directly through its walls leading to the open air.
As an indication, for every kW of power installed, an air renewal rate of
36 m
3
/h is recommended.
To get a clear idea of the specifications required for the housing location,
refer to the norms in force in the country where the installation is being
carried out, in particular those prescribed for this type of oven.
Summary of Contents for SYNTHESIS 08/50 V PW GAS
Page 2: ......
Page 38: ......
Page 45: ...SYNTHESIS 08 50 V PW GAS C 1 110 IMPI0138 ...
Page 46: ...SYNTHESIS 08 50 V PW GAS C 2 ...
Page 51: ...SYNTHESIS 08 50 V PW GAS ...
Page 52: ...SYNTHESIS 08 50 V PW GAS ...
Page 55: ...SYNTHESIS 08 50 V PW GAS ...
Page 56: ...SYNTHESIS 08 50 V PW GAS ...
Page 59: ...SYNTHESIS 08 50 V PW GAS ...
Page 60: ......
Page 64: ...SYNTHESIS BM A B ...