INSTALLATION
13
Synthesis
06/40V GAS
Take care that children do not play with the packaging materials ( e.g., plastic
sheeting and Styrofoam): suffocation danger!
4.4 POSITIONIG THE UNIT ON ITS BASE
Position the oven by sliding it into the four corners
of the basement (Fig.2).
4.5 POSITIONING STACKED UNITS
NO MORE THAN 3 UNITS SHOULD BE
STACKED ONE ON TOP OF THE OTHER
Once the first oven has been positioned on the base (see previous paragraph), proceed as
follows:
1 - Overlap consecutively the second and third module fit the chimney exhaust fumes and by
matching the exterior side walls of the ovens.
4.6 ELECTRICAL CONNECTION
Before making any connection, check that the specifications of the electrical supply to
which the equipment must be connected, correspond to the specifications of the power supply
required by the apparatus itself (see Tab. 3-1).
The appliances are supplied with an electric connection with ground/earth cable for
connecting the appliance to the power grid according to the supply required (see cap. 3.4
Tab. 3.1).
In compliance with the safety norms in force.
It is obligatory to connect the ground/earth
cable (yellow-green) to an earthing system with the same dispersion capacity as the
appliance itself. The efficiency of this system must be correctly verified according to
the norms in force.
The power cable must terminate with a plug to connect to the electrical switchgear having a
corresponding differential magneto thermal switch.
The equipment is not supplied with a power plug.
The coupling between plug and socket must be such that the earth conductor is connected
first and disconnected last and must have the right dimensions for the rated current (see Table
3-1). Plugs and sockets for industrial use of the type CEE17 are suitable or those which satisfy
European norm EN 60309.
2