OP7100
Installation
s
83
FD
JP5
1
2
0 V/GND
FGND
JP5
1
2
0 V/GND
FGND
Bezel/Casing to Power Supply
GND
Bezel/Casing to External Ground
External
Ground
External
Ground
JP4
JP5
JP3
Figure 6-1 shows the location of header JP5.
Figure 6-1. Location of Header JP5
Installation Guidelines
When possible, following these guidelines when mounting an OP7100.
1. Leave sufficient ventilation space
2. Do not install the OP7100 directly above machinery that radiates a lot
of heat (for example, heaters, transformers, and high-power resistors).
3. Leave at least 8" (20 cm) distance from electric power lines and even
more from high-voltage devices.
4. When installing the OP7100 near devices with strong electrical or
magnetic fields (such as solenoids), allow a least 3" (8 cm), more if
necessary.
The OP7100 has strong environmental resistance and high reliability, but
you can maximize system reliability by avoiding or eliminating the
following conditions at the installation site.
Abrupt temperature changes and condensation
Ambient temperatures exceeding a range of 0°C to 50°C
Relative humidity exceeding a range of 25% to 65%
Strong magnetism or high voltage
Corrosive gasses
Direct vibration or shock
Excessive iron dust or salt
Spray from harsh chemicals
Summary of Contents for OP7100
Page 1: ...OP7100 Serial Graphic Display User s Manual 019 0065 020418 J ...
Page 10: ...OP7100 x s About This Manual ...
Page 16: ...OP7100 16 s Overview ...
Page 50: ...OP7100 50 s Hardware ...
Page 72: ...OP7100 72 s Software ...
Page 80: ...OP7100 80 s Graphics Programming ...
Page 86: ...OP7100 86 s Installation ...
Page 96: ...OP7100 96 s Specifications ...
Page 110: ...110 s Serial Interface Board 2 OP7100 ...
Page 111: ...OP7100 Backup Battery s 111 APPENDIX E BACKUP BATTERY ...
Page 114: ...OP7100 114 s Backup Battery ...
Page 122: ...OP7100 122 s Index ...