Page 12
NJEX 610G / 610F ver.11-2023
Section 5: Programming the Z-100 Controller
When the system is ON, a
countdown to the next
pump stroke is shown."
SIGNALED:
The daily count of how many times
the controller actuated the 6000B pump.
SENSED:
The sensed number of strokes is only
displayed in a system with a flow switch (610F). If
you have a system without a flow switch, “NA” will
be displayed in the sensed total. For 610F systems,
the sensed total counts the number of strokes con-
firmed by the flow switch.
VOL CC:
For 610G systems, the daily CCs dis-
played on the Home Screen is a calculated value
dependent on the signaled daily total. For 610F
systems, the daily CCs displayed is a calculated
value dependent on the sensed daily total.
MASS (LB/KG):
Where VOL CC is displayed, it
will alternate between the volume and the mass of
odorant injected. For 610G systems, the daily mass
displayed on the Home Screen is a calculated value
dependent on the signaled daily total and the user
input density. For 610F systems, the daily mass
displayed is a calculated value dependent on the
sensed daily total and the user entered density.
Additional Features:
• If multiple alarms are present, the alarm type
will cycle on the home screen
• Hold the navigation switch for approximately
1 second to trigger a single test pump stroke
• Hold the navigation switch left for approximately
1 second to start or stop system
•
Bottom left has timer countdown to next pump
stroke in counter mode a % of accumulated
pulses is shown.
Totalizer:
From the Home Screen, you can navigate to the
Totalizer by pressing down on the navigation switch.
The totalizer is a running total of how much odor-
ant has been pumped. The date the totalizer was
started will be displayed at the top, along with the
current date and time.
Identical to the daily total, the 610G will show NA
for the sensed number of strokes.The screen will
cycle between the volume, displayed in gallons
or liters, and the mass, displayed in pounds or
kilograms. The 610G will calculate these numbers
based on the signaled stroke count while the 610F
will calculate these numbers based on the sensed
stroke count.
The totalizer can be reset by press enter on the
navigation switch and hold until the value and date
resets.
PUMP ALARM SCREEN (610F only):
If your sys-
tem has a flow switch from the home screen, the
pump alarm screen can be accessed by pressing
the navigation switch twice in the down direction.
The pump alarm screen shows the number of
strokes signaled (sent to the pump) and how many
strokes were sensed (counted by the flow switch).
The pump alarm will be triggered If the difference
between the signaled and sensed exceeds the DIFF
setting. The DIFF, or number of missed strokes that
will cause an alarm can be changed in the settings
menu. The pump alarm screen will be reset at mid-
night each day, therefore the threshold of missed
strokes must be surpassed that 24 hour period to
cause an alarm.