YZ Systems Milton Roy • 201 Ivyland Road • Ivyland, Pennsylvania • USA • 18974 • P: 281.362.6500 • www.yzsystems.com
Page 25
NJEX 610G / 610F ver.11-2023
Section 7: Mechanical System
NJEX LVO Gas Filter
A 25 micron coalescent filter is provided with each
610G / 610F. This filter, as shown, is installed
on the
back outside of the enclosure and should be con-
nected to the regulated (30-60 psi / 2.1-4.1 bar, per
) actuation gas supply provided by
the system operator. By conditioning the incoming
actuation gas, a clean pneumatic supply will be
provided to the solenoid valves. This will ensure
a longer operational life for the pneumatic control
system. If the actuation gas supply has a high water
content and / or a low hydrocarbon dew point, ad-
ditional filtration and heating of the actuation gas
supply may be necessary. Bottled nitrogen can also
be used as an alternate gas supply source if gas
conditioning is a problem.