Or
To View Real Time Displays
Choose *Dsp in the main menu, figure 113.
Strokes signaled are the number of pump strokes signaled by
the N-300 controller are shown in this display, figure 114.
To reset strokes signaled, press the *Rst key and
follow instructions, figures 115-115a.
Odorant Injected, figure 116,
is the cumulative total of
odorant injected in lbs. (kg) is shown in this display.
To reset lbs. (kg) injected, figures 117,
press the *Rst
key and follow instructions, figures 117-117a.
Note: Pounds – lbs. (kg) injected will increment only
when a valid pump displacement has been calculated.
Pounds – lbs. (kg) injected will not increment during fill
valve alarm condition.
Pump Displacement
This display illustrates the last value, in cc / stroke,
calculated by the N-300 with volume data supplied
by the Verometer, figure 118.
Note: an asterisk “*” following the value illustrated in the
display designates that a value has not been calculated
at present, and the previously set or programmed pump
displacement will be displayed,
ming Sections 5 & 6, beginning on pages 25 & 33.
Pump Alarms
There are three conditions that will result in a pump alarm
indication.
• Over Pumping, figure 119, the calculated pump dis-
placement exceeds the set pump displacement by 30%.
• Under Pumping, figure 120, the calculated pump displace-
ment is less than the set pump displacement by 30%.
• Pump Failure, figure 121, the calculated pump
displacement is less than the set pump displace-
ment by 75%. For example, low displacement due
to an empty meter, the pump cannot inject odorant
when required if the meter which supplies the
odorant to the pump is empty.
Figure 113
pmp bat vmtr sig tnk
PropFlow
Idle
*Strt *Dsp *Set
Figure 114
Figure 115
Figure 115a
pmp bat vmtr sig tnk
1.000 cc/Stroke *
Pump Displacement
pmp bat vmtr sig tnk
Reset Strokes?
*No *Yes
pmp bat vmtr sig tnk
Strokes Signaled
*Reset 01169284
pmp bat vmtr sig tnk
Strokes Signaled
*Reset 00000000
pmp bat vmtr sig tnk
Odorant Injected
*Reset 0.000lbs
pmp bat vmtr sig tnk
Odorant Injected
*Reset 0.000kg
pmp bat vmtr sig tnk
Reset lbs Injected?
*No *Yes
pmp bat vmtr sig tnk
Reset kg Injected?
*No *Yes
pmp bat vmtr sig tnk
Odorant Injected
*Reset 83.601lbs
pmp bat vmtr sig tnk
Odorant Injected
*Reset 1628.082kg
pmp bat vmtr sig tnk
0.690 cc/Stroke
Pump Displacement
pmp bat vmtr sig tnk
PropFlow
Idle
*Strt *Dsp *Set
Under Pump
Pump Failure
Figure 116
Figure 117
Figure 117a
Figure 118
Figure 119
Figure 120
Figure 121
pmp bat vmtr sig tnk
1.310 cc/Stroke
Pump Displacement
Over Pump