Setting Operator Input Parameters
• Choose Set in the main menu, figure 33.
• Choose Par – parameters in the set selection menu,
figure 34.
• Choose Flow in the set parameters menu, figure 35.
• Choose Set in the proportional-to-flow menu, figure 36.
Setting the odorant injection rate in
lbs/10K gallons(mg/liter) of LPG
To set the injection rate, figure 37, press and
release the Select key. The value entry will begin to
flash when chosen. Use the Up Arrow key to
increase the value and the Down Arrow key to
decrease the value. When a new value has been
chosen, press the Enter key to store the new value
into memory. The entered value will stop flashing
when it has been loaded into memory. Press the
Down Arrow key to advance to the next parameter.
Pump displacement in cc/stroke
To set the pump displacement,
figure 38, press and
release the Select key. The value entry will begin to
flash when chosen. Use the Up Arrow key to increase
the value and the Down Arrow key to decrease the
value. When a new value has been chosen, press the
Enter key to store the new value into memory. The
entered value will stop flashing when it has been loaded
into memory. Press the Down Arrow key to advance to
the next parameter.
Odorant density in lbs/gallon (g/cc) @ 60º F
To set the odorant density, figure 39,
press and
release the Select key. The value entry will begin to
flash when chosen. Use the Up Arrow key to
increase the value and the Down Arrow key to
decrease the value. When a new value has been
chosen, press the Enter key to store the new value
into memory. The entered value will stop flashing
when it has been loaded into memory. Press the
Down Arrow key to advance to the next parameter.
SSSSS
ECTION
ECTION
ECTION
ECTION
ECTION
5:
5:
5:
5:
5: P
P
P
P
P
R
RR
R
ROGRAMMING
OGRAMMING
OGRAMMING
OGRAMMING
OGRAMMING
FOR
FOR
FOR
FOR
FOR
P
P
P
P
P
R
RR
R
ROPOR
OPOR
OPOR
OPOR
OPORTION
TION
TION
TION
TIONAL
AL
AL
AL
AL
-----
TTTTTO
O
O
O
O
-F
-F
-F
-F
-F
LLLLLO
O
O
O
OW
W
W
W
W
O
O
O
O
O
PERA
PERA
PERA
PERA
PERATION
TION
TION
TION
TION
pmp bat vmtr sig tnk
PropFlow
Idle
*Strt *Dsp *Set
*designates optional key function
pmp bat vmtr sig tnk
Set Parameters
*Flow *Time *Esc
pmp bat vmtr sig tnk
Set Selection
*Par *Cal *Esc
Figure 33
pmp bat vmtr sig tnk
Proportional to Flow
*Set *Alarm *Esc
pmp bat vmtr sig tnk
Odorant Density
6.80 lbs/Gal
pmp bat vmtr sig tnk
Odorant Density
0.815 g/cc
pmp bat vmtr sig tnk
Injection Rate
lbs/10K G a l
pmp bat vmtr sig tnk
Injection Rate
16.0 mg/liter
Select
Enter
pmp bat vmtr sig tnk
Pump Displaceplent
1.000 cc/Stroke
Select
Enter
Select
Enter
Figure 34
Figure 35
Figure 36
Figure 37
Figure 38
Figure 39
pmp bat vmtr sig tnk
Set Parameters
*Flow *Time *Esc