Fitzroy Install NOV 2010
www.yunca.co.nz
Page 3 of 4
FIG C: HEATER DIMENSIONS – Fitzroy
(Drawings on this page not drawn to scale)
640
Ash Floor Protector
490
300
650
560
220
FIG D: HEATER POSITION.
* N.B.
Measurement “A” is taken from the top lip at the rear of the fire.
25
25
100
640
100
J
P
C
D
D
O
K
C
N
H
M
L
E
E
D
D
H
FIG D:
MINIMUM FIRE TO COMBUSTABLE WALL CLEARANCES –
FITZROY SUB 1.0
(WITH YUNCA FLUE MOUNTED SHIELD FITTED). Measurements in millimetres.
A
*
B
E
F
G
H
100
300
130
320
620
501
FIG D: MINIMUM FLOOR PROTECTION MEASUREMENTS
(WITH YUNCA FLUE MOUNTED SHIELD FITTED). Measurements in millimetres.
C
D
J
K
L
M
N
O
P
300
100
840
880
1274
1150
560
640
580
Above: Non combustible wall clearances
. Brick lining
from floor to within 25mm of ceiling. Leave air vents at the
bottom to allow airflow in the cavity. If Yunca flue mounted
shield is fitted, brickwork may be 1200mm high as long as
all vertical joints in top and bottom of brickwork are left out to
allow airflow when brickwork is capped.