Page 2 of 4 

FITZROY SUB 1.0 – TYPICAL INSTALLATION 

(not drawn to scale) 

 

FIG A (below, left):

 

FITZROY Sub 1.0 Flue Mounted Shield (Flue Guard) Kit.  

Complies (with heater) to AS/NZS 2918:2001 

 

5mm Max

50

LINER POSITIONED BY SPIDER
BRACKETS. TOP/BOTTOM

FLUE

TOP CAP (Fits inside flue)

FLASHING

25 MM BETWEEN LINER
AND ANY TIMBER.

TIMBER RAILS

SUPPORT ANGLES

25 mm min BETWEEN LINER
& ANY TIMBER

LINER POSITIONED BY SPIDER
BRACKETS TOP & BOTTOM.

SUPPORT ANGLES

300mm sq TIMBER FRAME

CEILING

1200mm BACK GUARD

    TERTIARY
 BACK GUARD
   

TWO SEISMIC RESTRAINT
attachment points.

6

0

0

m

m

 A

B

O

V

E

 T

H

E

 R

ID

G

E

 L

IN

E

 (

M

IN

*

If

 w

it

h

in

 3

.0

m

 o

ri

d

g

e

 l

in

e

*

1200mm FRONT GUARD

4

.6

 M

M

IN

IM

U

M

ASH FLOOR

PROTECTOR

650

300

100

900  Extension

Top Front 
  Angled

Lined

Deflector

65mm Gap

 

 

 
 
 
 
 

 

Note: All measurements are in millimetres. The rear 
clearance from the top rear lip of the fire is 100mm, 
i.e. 120mm from the (recessed) rear panel. 

 

CONDITIONS FOR FLUES 

(Refer Fig. E) 

 

1.  The FLUE shall extend to: 

 

Not less than 600mm above the highest 
point  on  the  roof  if  within  3.0m  of  that 
point, or 
Not less than 1000mm above the 
intersection point with the roof and not 
lower than any point of the roof within 
3.0m. 

 

In any case the length of the flue shall 
not be less than 4.6m from the ash floor 
protector. 

 

In some situations the Local Council 
may vary the above requirements. 

 

2.  The flue system must be tested and 

comply with AS/NZS2918:2001, 
Appendix F. 

 

3.  The insulation boundary shield shall be 

capable of preventing accidental 
migration of  loose-fill or any 
combustible material by any action of 
wind or by persons moving in the ceiling 
space.

 

 

These instructions, spare parts information, operation and maintenance guides may be 
downloaded from our website 

www.yunca.co.nz

 

 

CEILING PLATE

25mm min. BETWEEN LINER & ANY TIMBER

ENLARGEMENT OF CEILING ASSEMBLY

30

0

300mm Sq. TIMBER FRAME

TIMBER RAILS

SUPPORT ANGLES

LINER POSITIONED BY SPIDER
BRACKETS. TOP/BOTTOM

INSULATION BOUNDARY SHIELD

CUT CEILING MATERIAL
BACK 25mm CLEAR
OF BOUNDARY SHEILD.

CEILING

25

300

 

FIG B 

Summary of Contents for fitzroy

Page 1: ...walls Tested to AS NZS 2918 2001 by APPLIED RESEARCH SERVICES Clearance Rear Clearance from rear of top lip with YUNCA flue mounted shield fitted N B clearance from rear panel is 120mm 100 mm Side Clearance with YUNCA flue mounted shield fitted 300 mm Corner Clearance with YUNCA flue mounted shield fitted 130 mm F YUNCA Flue Kit Tested to AS NZS 2918 2001 Appendix F Fig A B E 1 4 2m x 150mm stainl...

Page 2: ... FLUES Refer Fig E 1 The FLUE shall extend to Not less than 600mm above the highest point on the roof if within 3 0m of that point or Not less than 1000mm above the intersection point with the roof and not lower than any point of the roof within 3 0m In any case the length of the flue shall not be less than 4 6m from the ash floor protector In some situations the Local Council may vary the above r...

Page 3: ...FLUE MOUNTED SHIELD FITTED Measurements in millimetres A B E F G H 100 300 130 320 620 501 FIG D MINIMUM FLOOR PROTECTION MEASUREMENTS WITH YUNCA FLUE MOUNTED SHIELD FITTED Measurements in millimetres C D J K L M N O P 300 100 840 880 1274 1150 560 640 580 Above Non combustible wall clearances Brick lining from floor to within 25mm of ceiling Leave air vents at the bottom to allow airflow in the c...

Page 4: ...THE MARKING TESTED TO AS NZS 4013 C ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS NZS 4013 D MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS WHERE SUCH ACTION ...