EM-0146-8
- -
10
Table 2.5d AMSE Controller Specifications
Table 2.5e Facilities
Model
AMSE-4AE-
(AMSE-2AE-)
AMSE-4BB-
(AMSE-2BB-)
AMSE-4DE-
Voltage
3-phase, AC 380 to 480 V, 50/60 Hz
(3-phase, AC 200 to 220 V/50 Hz, AC 200 to 240 V/60 Hz)
Permissible Voltage
Fluctuation
3-phase, AC 323 to 528 V, 50/60 Hz
(3-phase, AC 170 to 242 V/50 Hz, AC 170 to 264 V/60 Hz)
Main Circuit
Power
Permissible Frequency
Fluctuation
± 5 % or less
Command Signal Input
Voltage
0 to 10 V DC (Pressure/flow command input)
Command Signal Input
Impedance
10 k
Ω
Monitor Output Voltage
1ch. 0 to 10 V DC
(The output can be changed by parameters.)
Sequence Input Signal
12chs. Photocoupler input (current limiting resistance: 4.7 K
Ω
)
Power voltage: DC 21 to 27 V, short-circuited current: 4 to 6 mA
2chs. Relay output (contact capacity: AC 230 or DC 30 V, 0.3 A)
Interface
Sequence Output Signal
5chs. Open collector output (permissible load: DC 24 V, 0.1 A)
Cooling System
Forced fan cooling, enclosed (IP20)
Ambient Temp.
0 to 50 °C (no freezing)
Ambient Humidity
90 %RH or less (no condensation)
Environmental
Condition
Vibration 5.9
m/s
2
or less
Protective Functions
□
Overcurrent
□
Regenerative overvoltage
□
AMSE controller overload
□
Motor overload
□
Fin overheat
□
Instantaneous power failure
□
Undervoltage
□
Input open-phase
□
Output open-phase
□
Stall prevention
□
Ground fault overcurrent on the output side
□
Communication option error
□
Parameter memory device error
□
CPU error
□
Operation panel power short circuit
□
DC 24 power output short circuit
□
Inrush current limiting circuit error
□
Analog input error
□
Fan fault
□
Electronic thermal pre-alarm
□
Dynamic brake pre-alarm
□
PU stop
□
Brake transistor error
□
Parameter write error
□
Copy operation error
□
Operation panel lock
□
Parameter copy alarm
□
Communication error
□
USB communication error
□
Internal circuit error
□
Maintenance signal output
□
Error
□
Hydraulic control board error
□
Hydraulic control board warning
ASE3-
ASE5-
ASE10-
Model
4AA- AA- 4BZ- BZ-
CE-
Power Capacity
27 kVA
28 kVA
41 kVA
80 kVA
Current Breaker
100 A frame
/60 A
225 A frame
/125 A
100 A frame
/100 A
225 A frame
/175 A
225 A frame
/175 A
Electromagnetic Switch
N25
N50
N30
N80
N80