EM-0146-8
- -
14
2.7.3 Parts of the AMSE controller (internal parts)
Fig. 2.7c Parts of the AMSE Controller
■
Control Circuit Terminals
Connect wiring for I/O signals (see
the tables below).
- Table 2.7a Sequence Input
- Table 2.7b Analog I/O
- Table 2.7c Error Output
- Table 2.7d Sequence Output
- Table 2.7e Others
* The terminal arrangement is also
shown on the back side of the
upper cover.
■
USB Connector (Type B)
■
Operation Panel (PU) Power Terminal
×: Not used.
Do not connect wiring.
■
Sensor Terminals
Connect wiring for the pressure
sensor and thermistor.
- See Table 2.7f.
■
Combination Use Setting
Area
Configured when operating
the unit in combination use.
- See 8 Combination use.
■
Main Circuit Terminals
Connect wiring for AC power input, motor output,
grounding, and regenerative resistors.
- See Table 2.7g.
* The configuration varies depending on the model.
■
EMC Filter On/Off Connector
This system has a capacitive filter
and zero-phase reactor.
- See 7.3.
■
Used for the input of control
power separate from the
main circuit power.
- See 2.7.7.