Select "Arc Test" item in the menu and press the
key to confirm.
Now the screen displays as Figure A-2.
T Arc Test
2010-02-26 9:35 24
℃ 43%RH
X
Y
Figure A-2
Then start the Arc Test by pressing the
key. The process is as
follows:
a. The splicer puts the two fibers end profiles to the screen
center automatically and accomplishes gap setting and
aligning.
b. An electrical arc is produced by electrodes. Two fiber end
profiles are fused into ball shape.
c. The location of electrodes can be calculated according to the
change of fiber's shape, and displays the following
information.
If the electrode's position is on the left, the screen displays " Gap