Wiring diagram,
YLCA/YLHA PLUS 7, 9 TC and T, 400.3.50
I-2545g
YLCA/YLHA PLUS 7, 9
TC and
T
400.3.50
"B" mm Cu
2
L1
L1
L2
Q1
400V
, 3 ~,50Hz,
K2
(17)
AH
2
1
4
3
MS
1
F1
F1
F1
315 mA (LENT
O)
(SLO
W)
GO
G
N
D
D4
D2
D1
D3
P
LP
2,
5
bar
D5
G
N
D
N1
C
1
/
2
C5
N2
C
1
/
2
C
3
/
4
N3
N4
N5
C
3
/
4
1
2
3
4
5
6
7
8
9
10
11
12
A1
A2 (2)
N1
N4
N3
N5
C5
GO
G
B1
G
N
D
B2
G
N
D
B3
Y
ID
5
G
N
D
ID
3
ID
4
ID1
ID2
B1
B2
B3
B1
B2
B3
GND
B4
V+
GND
B4
J1
10
9
8
7
5
4
3
2
1
11
12
13
14
6
J2
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
L1
L3
L2
L3
L2
L3
5
6
A1
A2
3
1
2
3
0
C2
19
20
B4
M2
M1
K1
(16)
A1
A2
(5
)
3
~
F1
FUSIBLE PR
O
TECCIÓN CONTR
OL
ELECTR
ONICO / MANIOBRA 24V
24V ELECTR
ONIC CONTR
OL FUSE
F2
FUSIBLE PR
O
TECCIÓN
V
ARIADOR DE
VELOCID
AD
VENTILADOR
FAN SPEED CONTR
OLLER FUSE
FC
CONTR
OL DE F
ASES
PHASE CONTR
OL
FS
CONTR
OL CA
UD
AL DE
A
G
U
A
(UNID
ADES
TC)
W
ATER FLO
W SWITCH (TC UNITS)
FSC
V
ARIADOR
VELOCID
AD
VENTILADOR
FAN SPEED CONTR
OLLER
HP
PRESOS
TA
T
O AL
TA
41 BAR
HIGH PRESSURE SWITCH, 41 BAR
HTP
PR
O
TECT
OR
TÉRMICO RESISTENCI
A
HEA
TER
THERMAL PR
O
TECTION
K1
CONT
A
C
T
OR COMPRESOR
COMPRESSOR CONT
A
C
TO
R
K2
CONT
A
C
T
OR RESISTENCIA A
UXILIAR
A
UXILIAR
Y HEA
TER CONT
A
C
TO
R
LAK
A
CCESORIO LO
W AMBIENT
KIT PRESOS
TA
T
IC
O
LO
W AMBIENT KI
T,
A
CCESSOR
Y
LP
PRESOS
TA
T
O BAJ
A 2,5 BAR
LO
W PRESSURE SWITCH, 2.5BAR
M1
COMPRESOR
COMPRESSOR
M2
VENTILADOR
1
FAN
1
M3
BOMBA (UNID
ADES
TC)
PUMP (TC UNITS)
MS
INTERR
UPT
OR GENERAL
MAIN SWITCH
Q1
PR
O
TECT
OR MA
GNE
T
O
TÉRMICO
RESISTENCIA APO
Y
O
BA
CKUP HEA
TER MA
GNET
O
THERMAL
PR
O
TECT
OR
Q2
PR
O
TECT
OR MA
GNE
T
O
TÉRMICO GENERAL
/
COMPRESOR
MAIN MA
GNET
O
THERMAL PR
O
TECT
OR,
COMPRESSOR
Q3
PR
O
TECT
OR MA
GNE
T
O
TÉRMICO MANIOBRA
GENERAL 230V /
VENTILADOR / BOMBA
/
RESISTENCIA CAR
TER
MAIN OPERA
TING MA
GNET
O
THERMAL
PR
O
TECT
OR, 220V/F
AN/PUMP
.
SUMP HEA
TER
R00
SELECT
OR REM
O
T
O
P
A
R
O
/ MARCHA
ON/OFF REMO
TE CONTR
OL
RCH
SELECT
OR REM
O
T
O
FRIO / CALOR
COOL/HEA
T REMO
TE CONTR
OL
T
TRANSFORMADOR 230 / 24V 20V
A
230 / 24V 20V
A
TRANSFORMER
V4V
V
A
LVULA DE 4
VIAS
4-W
AY
V
A
LV
E
LOS COMPONENTES INCLUIDOS EN ESTOS RECUADROS SON ACCESORIOS STANDARD SUMINISTRADOS POR EL FABRICANTE
LOS COMPONENTES INCLUIDOS EN ESTOS RECUADROS NO SON SUMINISTRADOS POR EL FABRICANTE
1.-
ALARMA.
CONT
A
C
T
O
NORMALMENTE ABIER
T
O
LIBRE DE
TENSIÓN
(3A.RESISTIVOS MÁXIMO
)
ALARM.CONT
A
CT NORMALL
Y OPEN,
V
O
LT
-FREE (3A.
MAXIMUM RESIST
ANCE.
)
2.
-
SOND
A
TEMPERA
TURA EXTERIOR EN UNID
ADES CON LAK (NTC)
SOND
A
TEMPERA
TURA BA
TERIA EN UNID
ADES EST
AND
ARD (NTC)
OUTDOOR
TEMPERA
TURE PR
OBE ON UNITS
WITH LAK (NTC)
COIL
TEMPERA
TURE PR
OBE ON ST
AND
ARD UNITS (NTC)
NOTAS:
NOTES:
T
H
E
C
O
M
P
O
N
E
N
T
S
IN
C
LU
D
E
D
IN
T
H
E
S
E
B
O
X
E
S
A
R
E
N
O
T
S
U
P
P
LI
E
D
BY
THE MANUF
A
CTURER.
THE COMPONENTS INCLUDED IN
THESE BO
XES ARE ST
AND
ARD
A
CCESSORIES SUPPLIED BY
THE MANUF
A
CTURER.
3.
-
T
R
A
N
S
D
U
C
TO
R
D
E
P
R
E
S
IO
N
R
A
C
IO
M
E
T
R
IC
O
E
N
U
N
ID
A
D
E
S
C
O
N
L
A
K
SOND
A
TEMPERA
TURA EXTERIOR EN UNID
ADES EST
AND
ARD (NTC)
RA
TIOMETRIC PRESSURE
TRANSDUCER ON UNITS
WITH LAK,
OUTDOOR
TEMPERA
TURE PR
OBE ON ST
AND
ARD UNITS (NTC)
4.
-
SOLO UNID
ADES
TC
TC UNITS ONL
Y
(NO
TA
1)
(NO
TE 1)
COMPRESOR
COMPRESSOR
RESISTENCIA AUXILIAR
AU
XILIARY HE
ATER
VA
LVULA DE 4
VIAS
4-WAY
VA
LVE
BOMBA (NO
TA - 4)
PUMP (NO
TE 4)
(NO
TA - 4)
(NOTE - 4)
VERDE
GREEN
BLANCO
WHITE
NEGRO
BLACK
LAK (A
CCESORIO) (PRESIÓN)
LAK (A
CCESSOR
Y)
PRESSURE
TEMP
. EXTERIOR
OUTLET
TEMPER
AT
UR
E
(NO
TA
3)
(NO
TE 3)
ENTRADA
AG
UA
WATER INT
AKE
SALIDA
AG
UA
WATER OUTLET
(NOTA
2)
(NOTE 2)
(0)
N2
HTP
Q3
3A
FSC
LOAD
F2
L
N
Y
GND
T
230V
0V
20 VA
FS
P
HP
41
bar
R00
RCH
K1
V4V
2
UNITS
7
9
Q2
10
10
"B" mm
2
Cu
2,5
2,5
��
chiller
2
FC
(8
)
L1
L3
L2
14
11
FC
(1)
A
M
3
L1
L2
L3
N
24
21
22
1
2
3
4
5
6
L1
L1
N
N
Q2
Am
p
400V
, 3 ~,50Hz,N,
L2
L3
L2
L3
A
CONTR
OL ELECTRÓNICO
ELECTR
ONIC CONTR
OL
AH
RESISTENCIA A
UXILIAR
A
UXILIAR
Y HEA
TER
B1
SOND
A
TEMPERA
TURA ENTRAD
A
A
G
U
A
(NTC)
W
ATER INT
AKE
TEMPERA
TURE PR
OBE (NTC)
B2
SOND
A
TEMPERA
TURA SALI
D
A
A
G
U
A
(NTC)
W
ATER OUTLET
TEMPERA
TURE PR
OBE (NTC)
B3
SOND
A
TEMPERA
TURA (VER NO
TA
2) (NTC)
TEMPERA
TURE PR
OBE (SEE NO
TE 2) (NTC)
B4
(VER NO
TA
3)
(SEE NO
TE 3)
C2
CONDENSADOR
VENTILADOR
FAN CONDENSER
C2
CONDENSADOR
VENTILADOR
FAN CONDENSER
(SOLO YLHA)
(YLHA ONL
Y)
INST
ALAR
EN OBRA
INST
ALL
AT
JO
B
SITE
K2