262292-YTG-C-0707
40
Unitary Products Group
NOTE 1: HACR Type per NEC.
TABLE 27: WR ELECTRICAL DATA - HIGH STATIC DRIVE MOTOR W/O POWERED CONVENIENCE OUTLET
MODEL
(TONNAGE)
VOLTAGE
COMPRESSORS
OD FAN
MOTORS
FLA EACH
ID
BLOWER
MOTOR
FLA
CONV
OUTLET
AMPS
HEATER OPTION
MIN.
CIRCUIT
AMPACITY
(AMPS)
MAX. FUSE/
BRKR
1
SIZE
(AMPS)
RLA
EACH
LRA
EACH
MODEL
KW
STAGES
AMPS
180
(15)
208
22.4
164
2.1
20.0
0.0
None
-
-
-
78.8
100
E18
13.5
1
37.5
78.8
100
E36
27
2
74.9
118.7
125
E54
40.6
2
112.7
165.9
175
E72
54.1
2
150.2
175.2
200
230
22.4
164
2.1
20.0
0.0
None
-
-
-
78.8
100
E18
18.0
1
43.3
79.1
100
E36
36.0
2
86.6
133.3
150
E54
54.0
2
129.9
154.9
175
E72
72.0
2
173.2
198.2
225
460
10.9
100
1.2
10.0
0.0
None
-
-
-
39.3
50
E18
18.0
1
21.7
39.6
50
E36
36.0
2
43.3
66.6
70
E54
54.0
2
65.0
77.5
90
E72
72.0
2
86.6
99.1
110
575
8.3
78
0.9
7.5
0.0
None
-
-
-
29.8
35
E18
18.0
1
17.3
31.0
35
E36
36.0
2
34.6
52.7
60
E54
54.0
2
52.0
61.3
70
E72
72.0
2
69.3
78.7
90
240
(20)
208
30.1
225
2.4
38.6
0.0
None
-
-
-
118.1
150
E18
13.5
1
37.5
118.1
150
E36
27
2
74.9
141.9
150
E54
40.6
2
112.7
189.1
200
E72
54.1
2
150.2
198.4
225
230
30.1
225
2.4
38.6
0.0
None
-
-
-
118.1
150
E18
18.0
1
43.3
118.1
150
E36
36.0
2
86.6
156.5
175
E54
54.0
2
129.9
178.2
200
E72
72.0
2
173.2
221.5
250
460
15.5
114
0.9
19.3
0.0
None
-
-
-
58.7
70
E18
18.0
1
21.7
58.7
70
E36
36.0
2
43.3
78.3
80
E54
54.0
2
65.0
89.1
100
E72
72.0
2
86.6
110.7
125
575
12.1
80
0.6
16.2
0.0
None
-
-
-
46.9
60
E18
18.0
1
17.3
46.9
60
E36
36.0
2
34.6
63.6
70
E54
54.0
2
52.0
72.2
80
E72
72.0
2
69.3
89.5
100
300
(25)
208
42.3
245
2.4
38.6
0.0
None
-
-
-
143.4
175
E18
13.5
1
37.5
143.4
175
E36
27
2
74.9
143.4
175
E54
40.6
2
112.7
189.1
200
E72
54.1
2
150.2
198.4
225
230
42.3
245
2.4
38.6
0.0
None
-
-
-
143.4
175
E18
18.0
1
43.3
143.4
175
E36
36.0
2
86.6
156.5
175
E54
54.0
2
129.9
178.2
200
E72
72.0
2
173.2
221.5
250
460
17.6
125
0.9
19.3
0.0
None
-
-
-
62.9
80
E18
18.0
1
21.7
62.9
80
E36
36.0
2
43.3
78.3
80
E54
54.0
2
65.0
89.1
100
E72
72.0
2
86.6
110.7
125
575
14.5
100
0.6
16.2
0.0
None
-
-
-
51.7
60
E18
18.0
1
17.3
51.7
60
E36
36.0
2
34.6
63.6
70
E54
54.0
2
52.0
72.2
80
E72
72.0
2
69.3
89.5
100
VOLTAGE LIMITATIONS
ELECTRIC HEAT CORRECTION FACTORS
POWER SUPPLY
VOLTAGE
NOMINAL VOLTAGE
VOLTAGE
kW CAP. MULTIPLIER
MIN.
MAX.
208
208
1.00
VOLTAGE
LIMITATIONS
1
208/230-3-60
187
253
240
230
0.92
460-3-60
414
506
480
460
0.92
575-3-60
518
630
600
575
0.92
1.
Utilization Range “A” in accordance with ARI Standard 110.