262292-YTG-C-0707
Unitary Products Group
39
NOTE 1: HACR Type per NEC.
TABLE 26: WR ELECTRICAL DATA - STANDARD DRIVE MOTOR W/O POWERED CONVENIENCE OUTLET
MODEL
(TONNAGE)
VOLTAGE
COMPRESSORS
OD FAN
MOTORS
FLA EACH
ID
BLOWER
MOTOR
FLA
CONV
OUTLET
AMPS
HEATER OPTION
MIN.
CIRCUIT
AMPACITY
(AMPS)
MAX. FUSE/
BRKR
1
SIZE
(AMPS)
RLA
EACH
LRA
EACH
MODEL
KW
STAGES
AMPS
180
(15)
208
22.4
164
2.1
17.7
0.0
None
-
-
-
76.5
90
E18
13.5
1
37.5
76.5
90
E36
27
2
74.9
115.8
125
E54
40.6
2
112.7
163.0
175
E72
54.1
2
150.2
172.3
200
230
22.4
164
2.1
16.4
0.0
None
-
-
-
75.2
90
E18
18.0
1
43.3
75.2
90
E36
36.0
2
86.6
128.8
150
E54
54.0
2
129.9
150.4
175
E72
72.0
2
173.2
193.7
225
460
10.9
100
1.2
8.2
0.0
None
-
-
-
37.5
45
E18
18.0
1
21.7
37.5
45
E36
36.0
2
43.3
64.4
70
E54
54.0
2
65.0
75.2
90
E72
72.0
2
86.6
96.9
110
575
8.3
78
0.9
6.6
0.0
None
-
-
-
28.9
35
E18
18.0
1
17.3
29.9
35
E36
36.0
2
34.6
51.6
60
E54
54.0
2
52.0
60.2
70
E72
72.0
2
69.3
77.5
90
240
(20)
208
30.1
225
2.4
24.2
0.0
None
-
-
-
101.5
125
E18
13.5
1
37.5
101.5
125
E36
27
2
74.9
123.9
125
E54
40.6
2
112.7
171.1
175
E72
54.1
2
150.2
180.4
200
230
30.1
225
2.4
24.2
0.0
None
-
-
-
101.5
125
E18
18.0
1
43.3
101.5
125
E36
36.0
2
86.6
138.5
150
E54
54.0
2
129.9
160.2
175
E72
72.0
2
173.2
203.5
225
460
15.5
114
0.9
12.1
0.0
None
-
-
-
50.6
60
E18
18.0
1
21.7
50.6
60
E36
36.0
2
43.3
69.3
70
E54
54.0
2
65.0
80.1
90
E72
72.0
2
86.6
101.7
110
575
12.1
80
0.6
10.3
0.0
None
-
-
-
39.9
50
E18
18.0
1
17.3
39.9
50
E36
36.0
2
34.6
56.2
60
E54
54.0
2
52.0
64.8
70
E72
72.0
2
69.3
82.2
90
300
(25)
208
42.3
245
2.4
38.6
0.0
None
-
-
-
143.4
175
E18
13.5
1
37.5
143.4
175
E36
27
2
74.9
143.4
175
E54
40.6
2
112.7
189.1
200
E72
54.1
2
150.2
198.4
225
230
42.3
245
2.4
38.6
0.0
None
-
-
-
143.4
175
E18
18.0
1
43.3
143.4
175
E36
36.0
2
86.6
156.5
175
E54
54.0
2
129.9
178.2
200
E72
72.0
2
173.2
221.5
250
460
17.6
125
0.9
19.3
0.0
None
-
-
-
62.9
80
E18
18.0
1
21.7
62.9
80
E36
36.0
2
43.3
78.3
80
E54
54.0
2
65.0
89.1
100
E72
72.0
2
86.6
110.7
125
575
14.5
100
0.6
16.2
0.0
None
-
-
-
51.7
60
E18
18.0
1
17.3
51.7
60
E36
36.0
2
34.6
63.6
70
E54
54.0
2
52.0
72.2
80
E72
72.0
2
69.3
89.5
100
VOLTAGE LIMITATIONS
ELECTRIC HEAT CORRECTION FACTORS
POWER SUPPLY
VOLTAGE
NOMINAL VOLTAGE
VOLTAGE
kW CAP. MULTIPLIER
MIN.
MAX.
208
208
1.00
VOLTAGE
LIMITATIONS
1
208/230-3-60
187
253
240
230
0.92
460-3-60
414
506
480
460
0.92
575-3-60
518
630
600
575
0.92
1.
Utilization Range “A” in accordance with ARI Standard 110.