246721-YTG-C-0606
Unitary Products Group
5
FIGURE 2 - PREDATOR
®
MagnaDRY™ DR150
FEATURES
•
High Efficiency
– High efficiency units reach as high as
11.2 EER. Gas/electric units have electronic spark igni-
tion and power vented combustion with steady state effi-
ciencies of 80%. These efficiencies exceed all legislated
minimum levels and provide low operating costs.
•
Service Friendly
– The Predator
®
incorporates a num-
ber of enhancements which improve serviceability.
The motor and blower slide out of the unit as a common
assembly. This facilitates greater access to all the indoor
airflow components, thus simplifying maintenance and
adjustment.
Service time is reduced through the use of hinged, tool-
less panels. Such panels provide access to frequently
inspected components and areas, including the control
box, compressors, filters, indoor motor & blower, and the
heating section. The panels are screwed in place at the
factory to prevent access by children or other unautho-
rized persons. It is recommended that the panels be
secured with screws once service is complete.
Service windows have been placed in both condenser
section walls. Rotation of the cover allows easy access
to the condenser coils for cleaning or inspection.
Both the unit control board and ignition control board utilize
flash codes to aid in diagnosis of unit malfunctions. Unique
alarm codes quickly identify the source of the unit alarm.
All units use the same standard filter size. This standard-
ization removes any confusion on which filter sizes are
needed for replacement.
The non-corrosive drain pan slides out of the unit to per-
mit easy cleaning. The drain pan is accessed by remov-
ing the drain pan cover plate on the rear of the unit. Once
the plate is removed, the drain pan slides out through the
rear of the unit.
All Predator
®
units have a second model nameplate
located inside the control access door. This is to prevent
deterioration of the nameplate through weathering.
•
Environmentally Aware
– For improved Indoor Air Quality,
foil faced insulation is used exclusively throughout the units.
•
Balanced Heating
– The Predator
®
offers “Ultimate Heat-
ing Comfort” with a balance between 1
st
and 2
nd
stage
gas heating. The first stage of a gas heat Predator
®
unit
provides 60% of the heating capacity. Balanced heating
allows the unit to better maintain desired temperatures.
•
Convertible Airflow Design
– The side duct openings
are covered when they leave the factory. If a side supply/
Simplicity
™ Control
board w/screw
connectors for T-stat
wiring and Network
Connection
Disconnect
location (optional
disconnect switch)
Filter access
(2" throw-away)
Filter drier (solid core)
Condenser Section
Belt-drive blower
motor
Slide out motor
and blower
assembly for easy
adjustment and
service
Power ventor
motor
20-gauge
aluminized steel
tubular heat
exchanger for
long life
(stainless steel
option)
Two-stage gas heating to
maintain warm,
comfortable temperature
Intelligent control
board for safe and
efficient operation
Slide-out drain pan
with brass ¾" NPT,
female connection
Compressor #1 access
(high-efficiency
compressor w/crankcase
heater)
Side entry power
and control wiring
knockouts
Tool-less door
latch
Roof curbs in eight-and
fourteen-inch heights.
Roof curbs for
transitioning from York
Sunline TM footprint to
the DM/DH/DJ Series
footprint are available
(field-installed accessory)
Base rails w/
forklift slots
( three sides)
and lifting
holes
Compressor #2
access
(high-efficiency
compressor w/
crankcase heater)
Dual stage cooling
for maximum
comfort
Second model
nameplate inside
hinged access panel
Summary of Contents for PREDATOR MagnaDRY DR090
Page 11: ...246721 YTG C 0606 Unitary Products Group 11 FIGURE 4 DR090 120 REHEAT CONTROLS ...
Page 12: ...246721 YTG C 0606 12 Unitary Products Group FIGURE 5 DR150 REHEAT CONTROLS ...
Page 60: ...246721 YTG C 0606 60 Unitary Products Group FIGURE 41 DR090 AND 120 REHEAT WIRING DIAGRAM ...
Page 61: ...246721 YTG C 0606 Unitary Products Group 61 FIGURE 42 DR150 REHEAT WIRING DIAGRAM ...